Weil-McLain 550 MBH Nstallation And Operation Manual page 71

Commercial condensing gas-fired water boilers
Hide thumbs Also See for 550 MBH:
Table of Contents

Advertisement

®
SlimFit
Series 3
Control operation and setup
SlimFit control settings available in BASIC MODE (see Advanced Manual for ADVANCED MODE settings)
Boiler Model
Control Type
High Altitude
LP Gas
Manual Reset High Limit Temp
WWSD Temp
Adjust Outdoor
Circulator Exercising
Freeze Protect Circs
Reset Factory Default
Inputs Assigned (non-selectable)
System Type
Target Mod Sensor (non-selectable)
Target Adjust (non-selectable)
Supply Max
Supply Min (not available for DHW) *
OD Reset Max (or Volts for Max) *
OD Reset Min (or Volts for Min) *
Boost Time *
System types available in BASIC MODE (each option shown with factory settings)
8-Character
Abbreviation
Fan-coil
FAN-COIL
Finned Tube Baseboard
FIN BASE
Cast Iron Baseboard
IRONBASE
Cast Iron Radiators
RADIATOR
Radiant - slab on grade
RAD SLAB
Radiant - thin slab
RAD SLAB
Radiant - below floor
RADFLOOR
(staple up)
Radiant - above floor
RADFLOOR
(sleeper system)
Domestic Hot Water
DOMESTIC
XXXXXXXX
Custom (user defined)
(user input)
Part number 550-100-168/0516
COMMERCIAL CONDENSING GAS
Inputs Assigned (non-selectable)
System Type
Target Mod Sensor (non-selectable)
Target Adjust (non-selectable)
Supply Max
Supply Min (not available for DHW) *
OD Reset Max (or Volts for Max) *
OD Reset Min (or Volts for Min) *
Boost Time *
Inputs Assigned (non-selectable)
System Type
Target Mod Sensor (non-selectable)
Target Adjust (non-selectable)
Supply Max
Supply Min (not available for DHW) *
OD Reset Max (or Volts for Max) *
OD Reset Min (or Volts for Min) *
Boost Time *
* These items only appear in the menus if Target Adjust is active.
3-Character
Supply Max
Abbreviation
FCL
180
FTB
180
CIB
180
CIR
180
RSG
120
RTS
140
RSU
160
RAF
140
DHW
180
first three of
180
user input
-
FIRED WATER BOILER
(continued)
OD Reset
Supply
°F
Min °F
Min °F
0
140
0
130
0
120
0
120
0
80
0
80
0
90
0
90
N/A
N/A
0
70
Boiler Manual
Priority 1, 2 or 3
Source (TT1 or 0-10v)
AUX PUMP/OUTPUT
Off
Priority 1, 2 or 3
AUX PUMP/OUTPUT
Off
See Figure 67, page 77 for details.
See Figure 72, page 82 for details.
See Figure 72, page 82 for details.
OD Reset
Run
Max °F
Boiler Pump
70
YES
70
YES
70
YES
70
YES
70
YES
70
YES
70
YES
70
YES
N/A
NO
70
YES
Run AUX
PUMP/
OUTPUT
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES