9.2.

Indoor Power Relay Control

The Power Relay turns on under the following conditions.
1. For three minutes, when plugged in the A/C or the Error Reset button on remote controller is pressed.
2. During Installation Check Mode and following for three minutes after checking.
3. During On-timer sampling and during Preliminary operation.
4. During Operation and following for three minutes after the operation is stopped.
5. During Auto Operation, Test run, Forced Heating or Odour Removal Operation and following for three minutes after the
operation is stopped.
9.3.

Room Air Temperature Control (Compressor Control)

Operating frequency of a compressor is decided according to temperature differences between remote controller setting and
room temperatures. A relative method which gives frequency changes, based on the decided frequency, will provide you with
comfortable room environment that is not affected by operating conditions.
9.3.1.
Cooling Operation
9.3.1.1.
Thermostat Control
[Intake Air Temp. - Remote Controller Setting Temp.] >
[Thermostat-OFF Temp. +0.5 °C]
Operated in corresponding frequency.
Frequency is decided after a completion of the starting
control (in 60 seconds).
When Room Temp. is below [Thermostat-OFF Temp.]
continuously for 3 minutes or more, it turns to Thermostat-
OFF operation.
Outdoor Temperature, X (°C):
38
X
30
X
38
23
X
30
X
23
21
X
17
X
21
9
X
17
5
X
9
1
X
5
X
1
Mode:
Hi, Me-, Me, Me+, Auto
Mode within 60 Minutes from Start-up:
Temperature Shift (°C)
TE9DKE
0.00
0.00
0.00
0.00
0.00
0.00
0.00
+0.50
+1.00
+1.50
Fan Speed:
Temperature Shift (°C)
All
All
Lo
+0.25 (TE9DKE), +0.50
Temperature Shift (°C)
Cooling
Intake Air Temp.
Maximum
Difference (°C)
Intermediate
Minimum
(-1.00)
21
CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE
TE12DKE
0.00
0.00
0.00
0.00
0.00
0.00
0.00
+1.00
+1.25
+2.00
+1.25
+1.0
+1.0
(TE12DKE)
-1.0
+2.0
Power
TE9DKE
TE12DKE
2.7kW
Rated
2.5kW
~
0.8kW
OFF
—-
4.0kW
3.6kW
~
0.8kW
—-