9.4.
Airflow Direction Control
Vertical louver is controlled with Vertical Airflow Direction button on remote controller and by operation conditions, as shown in the
table below.
9.4.1.
Vertical Airflow Louver Angle
Manual Operation
It swings when airflow direction is set with
remote controller.
It does not swing while indoor fan is
stopped. (It is fixed at the upper limit.).
Fixed by Heat Exchanger Temperature
When Heat Exchanger Temperature is less
than 33°C
When Heat Exchanger Temperature is
between 33°C (, incl.) and 127°C
Odour Removal Control
The vertical louver is fully opened and move to the setting position when the unit is turned on with the remote controller.
The vertical louver remains open position when the unit is turned off during operation.
The horizontal louver is manually operated.
Cooling and Dry Operations
Airflow Direction Auto
Vertical Auto Operation
Heating Operation
Airflow Direction Auto
Powerful Operation
When Heat Exchanger Temperature is less
than 33°C
When Heat Exchanger Temperature is
between 33°C (, incl.) and 127°C
Airflow Direction Auto
The louver is fixed at five-level setting
position when the airflow direction is set with
remote controller.
The louver is fixed at five-level setting
position when the airflow direction is set with
remote controller.
23
CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE
Airflow Direction Setting
Powerful-ON
Airflow Direction Setting
Remote Control
Airflow Direction Setting