9.4.
Airflow Direction Control
9.4.1.
Horizontal and Vertical Directions
Vertical louver is controlled by remote control: the Vertical Airflow Direction button on the remote controller and by each operation
mode, as shown in the table below.
Manual Operation
Five-level setting is possible with the remote
controller.
Manual Operation
Five-level setting is possible with the remote
controller.
Manual Operation
Five-level setting is possible with the remote
controller.
Cooling Operation Mode
Vertical Automatic Operation
The louver swings between the upper limit
and the lower limit.
Dry Operation Mode
Vertical Automatic Operation
The louver is fixed at 12°.
Ion Operation Mode
Vertical Automatic Operation
The louver swings between the upper limit
and the lower limit.
23
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE
Powerful-ON
After Powerful is turned on, the louver is
fixed at 26° for 5 minutes or until the Neural
Control is stabilized.
After the Neural Control is stabilized, the
louver is fixed at 12°.
Power-ON (Automatic Operation)
The louver is fixed at 12°.
Power-ON (Automatic Operation)
The louver is fixed at 12°.