9.4.2.

Horizontal Airflow Direction Control

Operation
Mode
Cooling
Dry
Ion
Heating
When heat exchanger
temperature is below 32°C.
When heat exchanger is
between 32°C (, incl.) and 56°C
(, excl.)
When heat exchanger
temperature is 56°C or more.
Horizontal Automatic Operation
The louver horizontally swings at a fixed
cycle.
Horizontal Automatic Operation
The louver horizontally swings at a fixed
cycle.
Horizontal Automatic Operation
The louver horizontally swings at a fixed
cycle.
Horizontal Automatic Operation
When the Neural Control is stabilized.
The louver horizontally swings at a fixed
cycle.
When the Neural Control is not stabilized.
25
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE
Operation for 5 min. after Powerful-ON or
the Neural Control is stabilized.
Operation for 5 min. after Powerful-ON
The louver horizontally swings at a fixed
cycle.
Operation after Powerful-ON
The louver horizontally swings at a fixed
cycle.
Operation after Powerful-ON
In Quick Warm Operation
In Warm Heating Operation