CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU
Anti-Dew Formation is control by:-
Increasing Air Flow Volume
1. Lo fan speed.
Lo fan speed is changed to Lo+ after 30 min to prevent dew formation.
2. QLo fan speed.
Dew formation may occur at QLo cool, therefore QLo cool is operated only 1hr 30min (1 hr QLo, 30 min QLo + 80 rpm). After
that, it operates at QLo + 160 rpm (However Quiet LED remains on).
Narrowing
1. Vertical Airflow Direction
During Anti-Dew condensation prevention, Airflow Direction Auto-control angle from 0° - 32° to 20° - 30° under cooling and
Soft Dry operation mode.