HP StorageWorks XP12000 User Manual page 182

External storage xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

microprogram version 4.000 or later
Array type: EVA4000/6000/8000
microprogram version 5.031 or later
To replace the EVA array's microprogram, check whether the alternate path's behavior changes as
a result of changing the microprogram version. If the alternate path's behavior changes, perform
External Storage XP's Delete LU operation to release the setting for the EVA array volume's mapping
before you actually replace the microprogram.
See the EVA array manuals for more information how the alternate path's behavior changes.