Performance Data Sheet - Siemens KA**N series Installation Instructions And Instructions For Use

Table of Contents

Advertisement

en
Information concerning
the water filter
- After use, the water system is sub
ject to low pressure. Proceed with
caution when removing the filter.
- Flush the water system if the app
liance has not been in use for a
lengthy period, or if the ice/water
has an unpleasant taste or smell.
To do this, dispense water through
the water dispenser for several
minutes. If the unpleasant taste or
smell remains, replace the filter.
- Protect from frost. Remove the filter
cartridge if you expect the tempera
ture to drop below freezing.
Specification and output data sheet
Contaminant
reduction
Chlorine taste and odour
For cold water use only.
Application guidelines / water supply parameters
Service flow
Water supply
Water pressure
Water temperature
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Warranty: See warranty card.
Note that while the testing was performed under standard
laboratory conditions, actual performance may vary.
© 2003 CUNO Incorporated
INSTR4906 0203 [EN 2008]
14
- Do not install the water filter if
the water pressure is greater than
8.6 bar.
If the water pressure is greater than
5.5 bar, a pressure reducing valve
must be fitted. If you are not sure
what the water pressure is, contact
an installation expert.
- If pressure surges could occur in the
water pipe, do not install the water
filter without a suitable surge
eliminator. Contact an installation
expert if you are not sure whether
pressure surges could occur in the
water pipe.
- After installing a new filter:
Discard any ice produced in the first
24 hours after switching on.
These systems have been tested according to NSF/ANSI 42 for the reduction of the substances listed below.
The concentration of the substances indicated in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42.
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
chlorine taste and odour.
Capacity: 5,700 litres depending on local water conditions.
Contaminant reduction determined by NSF testing
Average
NSF specified influent
influent
challenge concentration
2.0
2.0 mg/l ± 10%
1.9 l/min
Public or private well
0.17 0.86 MPa (1.7 8.6 bar)
5 38 ºC

Performance Data Sheet

Models CS 451/CS 452
Avg. product
Avg. %
water
reduction
0.28
It is essential that operational maintenance and filter
It is essential that operational, maintenance and filter
replacement requirements be carried out for this
replacement requirements be carried out for this
product to perform as advertised. Change cartridges
product to perform as advertised. Change cartridges
every 6 months. Flush new cartridge for 5 minutes.
Use replacement cartridges CS 51 or CS 52.
Use replacement cartridges CS 51 or CS 52
For service and parts contact your local dealer or:
p
- If no ice has been removed for a
lengthy period: Empty the ice box
and discard any ice produced over
the next 24 hours.
- The ice and water dispenser can
also be used without a water filter,
in which case the locking cap must
be used.
2.
1.
NSF reduction
requirements
86
≥ 50%
y
CUNO Incorporated
400 Research Parkway
Meriden, CT 06450, USA
Worldwide: 203 237 5541
Fax: 203 238 8701
NSF Test
503821 01