Window Master futurevent Installation Instructions Manual

Control unit (wfc) and interface (wfi)
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

FutureVent™
EN – Installation instruction – control unit (WFC) and Interface (WFI)
DK – Installationsvejledning – styreenhed (WFC) og interface (WFI)
DK
+45 4567 0300
UK & IE
+44 (0) 1536 510990
+49 (0) 5221 6940 – 500 Vertrieb / -650 Technik
DE
CH
+41 (0) 62 289 22 22
Other markets
+45 45 37 0300
FutureVent–install_WFC_WFZ_UK_DK_1602
info.dk@windowmaster.com
info@windowmaster.co.uk
info@windowmaster.de
info@windowmaster.ch
info@windowmaster.com
©WindowMaster 2016
®WindowMaster is a registered trademark used under license by WindowMaster Group
www.windowmaster.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the futurevent and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Window Master futurevent

  • Page 1 FutureVent™ EN – Installation instruction – control unit (WFC) and Interface (WFI) DK – Installationsvejledning – styreenhed (WFC) og interface (WFI) +45 4567 0300 info.dk@windowmaster.com UK & IE +44 (0) 1536 510990 info@windowmaster.co.uk +49 (0) 5221 6940 – 500 Vertrieb / -650 Technik info@windowmaster.de...
  • Page 2: Table Of Contents

    System overview ................................3 Generel information ............................... 3 Electrical installation ..............................4 Cable entries in the unit ............................4 The connections of the FutureVent™ unit ......................... 4 Service point ................................. 4 FutureVent™ bus connection ............................ 4 230V supply ................................5 ®...
  • Page 3: System Overview

    Generel information Each FutureVent™-unit has a built in control intelligence with five analogue inputs, one analogue output and one digital output. The units communicate mutually via FutureVent™ bus (FV-Bus) and must therefore be connected to 230V and FutureVent™...
  • Page 4: Electrical Installation

    All electrical installations must be done by an authorized company according to national rule and regulation. Cable entries in the unit Cables can be pulled hidden into the unit via insertion holes in the housing. See the mounting instruction (”FutureVent Install WFV_WFB_WFR_WFC_WFD_WFS_WFG_UK_DE_DK_xxxx”) for further details. Cables must be relieved according to applicable rules and would benefit from being stripped near the intake holes.
  • Page 5: 230V Supply

    The length and distance specifications must adhere to the above table. FutureVent™ bus is a ”free topology” meaning it can be connected as a bus, a star or a combination of the two.
  • Page 6: Troubleshooting On The Futurevent™ Installation

    Only a few units of the installation are running: With an ohmmeter check the FutureVent™ bus for short circuits. If it is suspected that some of the units are not correctly connected to the FutureVent™ cable, insert a 10k resistor parallel across the bus, and troubleshoot by measuring the resistance on the FutureVent™...
  • Page 7: Elektrisk Installation

    Alle elektriske tilslutninger til anlægget skal udføres af autoriseret firma iht. gældende love og regler. Kabelindføringer i enheden Kabler kan indføres skjult i enheden via indføringshuller i kabinettet. Der henvises til montagevejledningen (”FutureVent Install WFV_WFB_WFR_WFC_WFD_WFS_WFG_UK_DE_DK_xxxx”). Kabler skal aflastes efter gældende regler og kan med fordel af-isoleres tæt på...
  • Page 8: Futurevent-Bus Forbindelse

    Længde og afstandskrav skal overholde afstande angivet i ovenstående tabel. FutureVent™-bus er ”free topology” hvilket betyder, at det kan kobles både som bus og stjerne, eller en kombination heraf.
  • Page 9: Kontrol Af Elektrisk Installation

    Kontroller FutureVent™-bussen for kortslutninger med et ohmmeter. Hvis der er mistanke om, at nogle af enhederne ikke er tilsluttet FutureVent™-buskablet korrekt, så monter evt. en 10k modstand parallelt over bussen og fejlfind ved at måle modstanden på FutureVent™-bussen lokalt ved enhederne.

Table of Contents