Check Apparatus; Record Test Details - Scott Contour User Instructions

Self-contained breathing apparatus
Table of Contents

Advertisement

CONTOUR
Pump dispensers are available for the
above under Article Numbers 1017672 (1
litre) and 1017670 (5 litres).
TriGene
disinfecting wipes are available
TM
from Scott Health and Safety Limited
under Article Number 2004225 (pack of
20).
7.
The harness can be sponged clean
with a mild solution of soap and warm
water. Rinse thoroughly and dry in a well
ventilated room away from direct heat and
sunlight.
8.
Fully
slacken
shoulder
straps
and
detach the lumbar pad. Release the hose
retaining
press-studs
separate
the
pneumatics
harness.
9.
In extreme cases, remove the
pneumatics from the harness to gain full
access for cleaning. The lumbar pad
filling is closed-cell foam that will not
absorb water. DO NOT store until
completely dry.
CAUTION:
DO NOT immerse the DV.
10.
Fit the yellow cap on the DV outlet.
11.
If required use a small brush (e.g.
toothbrush) and a mild solution of soap
and warm water to clean around the
locking catch and bypass knob.
12.
Clean the valve body using a lint
free cloth moistened in a mild solution of
soap and warm water. DO NOT store until
completely dry.
cylinder
band,
waist-belt;
and
(if
fitted)
and
from
the
18
6.2

CHECK APPARATUS

1.
Operate the DV locking catch and
bypass knob several times and check that
they do not stick. If either is not free
moving, attach explanatory note and
return for servicing.
2.
Check that the harness webbing
and fittings are not worn or damaged; and
that buckles and fastenings are fully
operational. Apparatus with major defects
must be returned for servicing, with an
explanatory label attached.
3.
Check Contour in accordance with
Section 3 - Pre-Use and Monthly Checks.
6.3

RECORD TEST DETAILS

Record test details in accordance with
local
regulations
within
Apparatus Logbook (available from Scott
Health and Safety Limited under Article
Number 1034745).
Information recorded usually includes:
Name and address of employer
responsible for the apparatus.
Make, model number or mark
description of any distinguishing
features, sufficient to enable clear
identification.
The
date
of
together with the name, signature
or unique authentication mark of
the examiner.
The condition of the apparatus and
details of any defects found and
any remedial action taken, including
any airline supply equipment used
with the apparatus.
Cylinder air pressure.
a
Breathing
the
examination