Installation and connection

This dryer must only be installed and
commissioned by a Miele authorised technician.
This appliance must be installed in accordance with
local and national safety and building regulations by
a suitably qualified engineer. It must only be operated
in a room with sufficient ventilation.
Read the instructions supplied with the appliance
before installing and using it for the first time.
Do not install the tumble dryer in a room where there
is a risk of frost occurring.
Use a suitable fork-lift to transport the dryer to its final
location. Caution. Danger of tipping.
Remove the transport packaging. Unscrew the Torx T
20 and 30 screws on the wooden pallet and remove
the wooden battens.
Using a suitable fork-lift, raise the dryer and fit the
four feet supplied.
22
To ensure suitable access for future maintenance and
service work, please ensure that the minimum
distances between the dryer and the wall specified
on the installation diagram are strictly observed.
A gas appliance shall be installed such that the
surface temperature of any nearby combustible
surface will not exceed 65 °C above ambient.
The appliance must not be installed behind a
lockable door, a sliding door or a door with a hinge
on the opposite side to that of the tumble dryer, in
such a way that a full opening of the tumble dryer is
restricted.
PT 830x
x
1800 mm
y
710 mm
z
1090 mm