Cobra UK75 ST Operating Instructions Manual page 18

Wj-nd400k
Table of Contents

Advertisement

UK75ST-English-UK.qx
6/15/99 3:57 PM
31
FREQUENCY RANGE Continued
European (CEPT)
Channel Freq.
CB Channel
in MHz
1
26.965
2
26.975
3
26.985
4
27.005
5
27.015
6
27.025
7
27.035
8
27.055
9
27.065
10
27.075
11
27.085
12
27.105
13
27.115
14
27.125
15
27.135
16
27.155
17
27.165
18
27.175
19
27.185
20
27.205
Page 36
European (CEPT)
Channel Freq.
CB Channel
in MHz
21
27.215
22
27.225
23
27.255
24
27.235
25
27.245
26
27.265
27
27.275
28
27.285
29
27.295
30
27.305
31
27.315
32
27.325
33
27.335
34
27.245
35
27.355
36
27.365
37
27.375
38
27.385
39
27.395
40
27.405
UK75ST SPECIFIC ATIONS
GENERAL
CHANNELS
FREQUENCY RANGE
FREQUENCY TOLERANCE
FREQUENCY CONTROL
OPERATING TEMPERATURE RANGE
MICROPHONE
INPUT VOLTAGE
ANTENNA CONNECTOR
METER
SIZE
WEIGHT
TRANSMITTER
POWER OUTPUT
MODULATION
FREQUENCY RESPONSE
OUTPUT IMPEDANCE
RECEIVER
CB
SENSITIVITY
IF FREQUENCY
AUDIO OUTPUT
FREQUENCY RESPONSE
2ND IF IMAGE REJECTION
ADJACENT CH. REJECTION
FREQUENCY CONTROL
32
CB - EUROPEAN (CEPT) 40 CH
CB - UK 40 CH
CB - EUROPEAN (CEPT): 26.965 TO
27.405 MHz
CB - UK: 27.60125 TO 27.99125 MHz
± 500 Hz
PLL (PHASE LOCK LOOP) SYNTHESIZER
-20°C TO + 60°C
ELECTRET, PUSH-TO-TALK
13.2 V d.c., EXTERNAL
SO 239
LCD DISPLAY, ICONS
L 70 mm x W 48 mm x H 108 mm
(L 2 3/4" x W 1 7/8" x H 4 1/4")
453g (1 LB.)
4.0 W AT 13.2 V d.c.
FM
300 - 3000 Hz AT -6 dB
50 OHMS, UNBALANCED
LESS THAN 6 dB µV FOR 20 dB Sinad
DUAL CONVERSION
1ST - 10.690 MHz, 2ND - 455 kHz
500 mW MAXIMUM AT 10 % THD
300 - 3000 Hz AT -6 dB
GREATER THAN 70 dB
60 dB MIN.
PLL (PHASE LOCK LOOP)