Inspect the proper function of the air
filtration system daily.
Replace clogged filters.
Clean the unit regularly.
Defective safety devices must be
replaced immediately.
Repair and maintenance work on the
electrical system may only be carried
out by a qualified electrician.
7.1 Changing Filters
Disconnect the machine from the
power source.
During the changing or cleaning of
the filters it's necessary to use a
mask (mask with filtration).
There are two filters that need to be
changed.
Fig 4
The outer filter (A, Fig 4) can easily
be removed by disengaging the two
clips (B, Fig 4).
Now you can simply pull the filter out.
The optionally availabel charcoal
outer filter can be used to reduce
certain chemical air contaminations.
The inner filter (C, Fig 4) can be
pulled out of the unit.
The inner filter can be blown out with
air (to be done outside of building
only!), or replaced.
The filters should be replaced
depending on the amount of usage
and the environment of your shop.
There is an arrow indicating the air
flow direction on the filters.
Make sure the filters are inserted
facing the proper direction.
8. Trouble shooting
Unit doesn't start
*No electricity-
check mains.
*Defective switch, motor or cord-
consult an electrician.
Air flow too weak
*Clogged outer filter-
Blow out with air or replace.
*Clogged inner filter-
Blow out with air or replace.
9. Available accessories
Stock number 708731
Electrostatic outer filter (5 Micron,
replacement filter)
Stock number 708735
Inner filter (1 Micron, replacement
filter).
Stock number 708734
Charcoal outer filter (replacement
filter, reduces certain chemical air
contaminations).