Zwbr 11-35 N; Zwbr 14-35 L.p.g; Heating/Hot Water Output Settings Zwbr 11-35 N.g - Worcester ZWBR 7-28 HE plus Installation And Servicing Instructions

Wall mounted condensing boiler for central heating and mains fed domestic hot water
Hide thumbs Also See for ZWBR 7-28 HE plus:
Table of Contents

Advertisement

10.5 Heating/hot water output settings ZWBR 11-35 N.G.

Display
Heat output,
code
kW
30
10.5
40
14.1
50
17.6
60
21.1
70
24.6
80
28.1
90
31.6
100
35.1
Table 22
10.6 Heating/hot water output settings ZWBR 14-35 L.P.G
Propane
Display
Heat output,
code
kW
40
14.1
50
17.6
60
21.1
70
24.6
80
28.1
90
31.6
100
35.1
Table 23
6 720 610 597 GB (01.07)
Natural gas G20
Heat input,
Gas vol. flow rate (l/min at t
kW
10.7
18.6
14.2
24.9
17.8
31.1
21.3
37.3
24.9
43.5
28.4
49.7
32.0
55.9
35.5
62.1
Heat input ,
kW
14.2
17.8
21.3
24.9
28.4
32.0
35.5
/t
= 80/60 °C)
V
R
Appendix
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zwbr 11-35 he plus

Table of Contents