5. Slide the quick change ring up over the element and rotate
counter clockwise until an audible click or pop is heard. If you
do not hear the click you have not rotated the ring far enough
and the element is not in the locked position. Another
indication that the ring is in the locked position is that one set
(it doesn't matter which one) of arrows located on the outside
of the ring should be located directly under the air vent valve.
6. Remove the see-through bowl from the old element and
install on the new element.
7. Open the fuel shutoff valve.
8. Open the air vent valve on the front of the filter header until
fuel emerges free of air bubbles and then close the air vent
valve.
Note: Consult your engine operation manual for information
on air bleeding the entire fuel system.

Engine and Maintenance components

ITEM
MAKE
Engine Air Filter
Donaldson
Fan Belt
Perkins
Fuel Filter
Perkins
Engine Oil Filter
Perkins
Lincoln
Pre-Filter/Water
Separator Element
Stanadyne

SPARK ARRESTOR

SAE-400® with integral spark arresting mufflers:
Service spark arrester every 250 hours.
Service as follows:
1. Stop engine and allow to cool.
2. Remove clean out plug from side of spark arrester.
PART NUMBER
3. Without damaging the spark arrester, gently tap on the
P822768
4. Once particles are removed, replace the clean out plug.
2614B555 043
26560201

GFCI Testing AND RESETTING Procedure

The GFCI should be properly tested at least once every month or
2654407
whenever it is tripped. To properly test and reset the GFCI:
M21584-B
• If the GFCI has tripped, first carefully remove any load and
39420 LE
• If the equipment has been shut down, it must be restarted.
• The equipment needs to be operating at high idle speed and
• The circuit breaker for this receptacle must not be tripped.
• Push the "Reset" button located on the GFCI. This will assure
• Plug a night-light (with an "ON/OFF" switch) or other product
• Push the "Test" button located on the GFCI. The night-light or
• Push the "Reset" button, again. The light or other product
If the light or other product remains "ON" when the "Test" button
is pushed, the GFCI is not working properly or has been incorrectly
installed (miswired). If your GFCI is not working properly, contact a
qualified, certified electrician who can assess the situation, rewire
the GFCI if necessary or replace the device.
D-3
WARNING
Spark Arrester and Muffler may be hot!
Allow engine to cool before servicing
spark arrester!
Do not operate engine while servicing
spark arrester!
arrester shell near the clean out plug.
check it for damage.
any necessary adjustments made on the control panel so that
the equipment is providing at least 80 volts to the receptacle
input terminals.
Reset if necessary.
normal GFCI operation.
(such as a lamp) into the Duplex receptacle and turn the
product "ON".
other product should go "OFF".
should go "ON" again.