Troubleshooting Procedures
To avoid risk of electrical shock, personal injury, or death; disconnect power and shut off gas to unit before
servicing, unless testing requires power.
Problem
Burner will not ignite; spark present
at igniter.
Continual sparking after ignition
12
Possible Cause
Low gas pressure..............................
Burner cap not seated correctly or
ports blocked.....................................
Weak or failed spark module............
Improper wiring - spark lead does
not correspond to igniter switch.........
Burner cap not seated correctly or
ports blocked.....................................
Shorted micro switch/harness...........
Switch is not properly seated on
valve stem.........................................
Bad connection to ground..................
Faulty spark lead...............................
SMC-0002
Correction
•
Verify pressure of 5" WCP for
natural gas; 10" WCP for liquid
propane
•
Verify proper seating and clean
ports
•
Replace spark module
•
Check all connections against
wiring diagram
•
Verify proper seating and clean
ports
•
Replace igniter harness.
•
Carefully reposition switch on
valve and verify the switch is
functional (see Component
Testing Procedures)
•
Verify a clear path to ground.
Clean and dry all metal contact
points along ground path to
ensure continuity
•
Test/replace - presence of
spark alone does not indicate a
functional lead
© Viking Range Corporation