Carrier 58CTA/CTX Product Data page 12

Table of Contents

Advertisement

DIMENSIONS
(733mm)
(664mm)
28-7/8"
26-1/8"
(FLUE COLLAR)
(641mm)
25-1/4"
22-9/16"
(573mm)
JUNCTION BOX
LOCATION
5-15/16"
(135mm)
(22mm)
7/8" DI A
ACCESSORY
1/2" (13 mm) DIA.
THERMOSTAT WIRE ENTRY
3-15/16" (84mm)
LEFT HAND GAS
ENTRY
33-5/16"
(846mm)
7/8" (22mm) DIA.
ACCESSORY
11/16"
(549mm)
(17mm)
21-5/8"
BOTTOM INLE T
24"
CASING
(610mm)
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM ---16 ---in. (406 mm) round or 14 1/2 x 12 ---in. (368 x 305 mm) rectangle.
b. For 1200 CFM ---20 ---in. (508 mm) round or 14 1/2 x 19 1/2 ---in. (368 x 495 mm) rectangle.
c. For 1600 CFM ---22 ---in. (559 mm) round or 14 1/2 x 22 1/16 ---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
A
CABINET
WIDTH
FURNACE SIZE
IN (mm)
045---08
14--- 3/16 (360)
045---12
14--- 3/16 (360)
070---08
14--- 3/16 (360)
070---12
14--- 3/16 (360)
070---16
17--- 1/2 (445)
090---14
17--- 1/2 (445)
090---16
21 (533)
090---20
21 (533)
110---12
17--- 1/2 (445)
110---16
21 (533)
110---22
21 (533)
135---16
21 (533)
135---22
24--- 1/2 (622)
155---20
24--- 1/2 (622)
* 5 ---in. or 6 ---in. (127 or 152 mm) vent connector may be required in some cases.
{ 135 and 155 size furnaces require 5 ---in. (127 mm) or larger vents. Use a 4 to 5 or 4 to 6 ---in. (102 to 127 or 102 to 152 mm) vent adapter between furnace and
vent connector.
A
D
F
24-7/8"
(632mm)
5-1/2"
E
(140mm)
1-11/16"
(43mm)
D
E
SUPPLY ---AIR
RETURN---AIR
WIDTH
WIDTH
IN (mm)
IN (mm)
12--- 9/16 (319)
12--- 11/16 (322)
12--- 9/16 (319)
12--- 11/16 (322)
12--- 9/16 (319)
12--- 11/16 (322)
12--- 9/16 (319)
12--- 11/16 (322)
15--- 7/8 (403)
16--- 1/8 (410)
15--- 7/8 (403)
16--- 1/8 (410)
19--- 3/8 (492)
19--- 1/2 (495)
19--- 3/8 (492)
19--- 1/2 (495)
15--- 7/8 (403)
16--- 1/8 (410)
19--- 3/8 (492)
19--- 1/2 (495)
19--- 3/8 (492)
19--- 1/2 (495)
19--- 3/8 (492)
19--- 1/2 (495)
22--- 7/8 (581)
23 (584)
22--- 7/8 (581)
23 (584)
2-7/16"
(62mm)
1-5/16"
(33mm)
13/16"
1-1/8"
(21mm)
(29mm)
4-13/16"
(122mm)
1/2" DIA. K.O.THERMOSTAT
WIRE ENTRY
8-9/16"
1-3/4" DIA.RIGHT HAND
(217mm)
GAS ENTRY
7/8" DIA. K.O. WIRE ENTRY
ALTERNAT E
(22mm)
JUNCTION BOX
LOCATIONS (TYP)
VENT OUTLE T
5 PLACES (TYP)
7/8" DIA. ACCESSORY
(22mm)
5-1/2"
(140mm)
1-1/2"
11/16"
3-3/4"
(17mm)
(95mm)
F
CENTER LINE
FLUE
TOP AND
COLLAR*
BOTTOM FLUE
IN (mm)
COLLAR
IN (mm)
9--- 5/16 (237)
4 (102)
9--- 5/16 (237)
4 (102)
9--- 5/16 (237)
4 (102)
9--- 5/16 (237)
4 (102)
11--- 9/16 (294)
4 (102)
11--- 9/16 (294)
4 (102)
13--- 5/16 (338)
4 (102)
13--- 5/16 (338)
4 (102)
11--- 9/16 (294)
4 (102)
13--- 5/16 (338)
4 (102)
13--- 5/16 (338)
4 (102)
13--- 5/16 (338)
4 (102)
15--- 1/16 (383)
4 (102)
15--- 1/16 (383)
4 (102)
12
AIRFLOW
19"
13/16"
(483mm)
(21mm)
OUTLE T
9-5/8"
(13mm)
11/16"
7-3/4"
(17mm) (197mm) (244mm)
(44mm)
11-1/2"
(292mm)
14-7/8"
(378mm)
(38mm)
1-1/4"
(560mm)
(32mm)
22-1/16"
1"
SIDE INLE T
(25mm)
A04037
FILTER
MEDIA
SHIP WT
CABINET
LB (KG)
IN (mm)
104 (47)
16 (406)
107 (48)
16 (406)
111 (50)
16 (406)
115 (52)
16 (406)
126 (57)
16 (406)
127 (58)
16 (406)
140 (64)
20 (508)
146 (66)
20 (508)
135 (61)
16 (406)
146 (66)
20 (508)
152 (69)
20 (508)
149 (68)
20 (508)
{
163 (74)
24 (610)
{
170 (77)
24 (610)
{

Hide quick links: