Error codes
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Sequence test program VA(9)6211TT
0 Pumping
1 Opto sensor PTC switched on
2 Filling soft water - Aqua sensor - Opto sensor
3 Pause - Aqua sensor (red)
4 Filling hard water - Aqua sensor (red)
5 Pause - Aqua sensor (red)
6 Filling hard water - Aqua sensor (red)
7 Pause
8 Aqua sensor (green)
9 Outlet valve heat exchanger
10 Regeneration valve
11 Control soap di s penser
12 - 17 water renewal positioning
18 Circulation pump (relay sub coil sicasym)10 + 20
19 Water renewal positioning
20 Circulating
21 Circulating + heating
22 Pumping
23 Circulating
Product information
VA3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S.. T
MPr 28112005
23 -
Aqua sensor calibrating error red sensor
Aqua sensor calibrating error green sensor
No tacho pulse
Circulation pump short circuit
No pulse from water hardness sensor
Filling error
Triac water hardness sensor short circuit
Heating error
- - -
- - -
NTC error, interrupted / short circuit
Opto sensor, error or no communication ( does not apply)
Relay power supply stuck
Net synchronisation not possible
Safety level activated
Safety level (O) 8 x recognized
20
250
30
2
1 litre
2
1 litre
2
tot F1
2
60
60
10
90
BK / OK
OK
BK
BK
max. 67 °C
Rinsing
5