Worcester GREENSTAR 29 Installation And Servicing Instructions page 36

Wall mounted condensing boiler
Table of Contents

Advertisement

Maintenance
Diaphragm in mixer unit
B Take care not to damage diaphragm
(443) when removing and refitting it.
B Open mixer unit (29).
B Carefully withdraw diaphragm (443) from fan intake
tube and check for soiling and splits.
3.
1.
2.
6 720 610 790-07.2R
Fig. 55
B Carefully refit diaphragm (443) the correct way
round into the fan intake tube.
The flaps of the diaphragm (443) must
i
open upwards.
B Seal the mixer unit (29).
Siphon
B Unscrew the clip and disconnect the pipe to the
siphon.
B Remove the yellow plug to drain the siphon.
B Unscrew the securing nut from beneath the side
facia and remove the siphon. Refer to figure below.
36
443
29
B Refit and prime the siphon.
Condensate
Drain
Siphon
Fig. 56
Electrical wiring
B Check the electrical wiring for physical damage and
replace any damaged wires.
6 720 611 137 - 22. 1O
6 720 611 137 GB (03.02)