Fan Blade Removal And Replacement - Oreck Super Air 5 447628 Service Manual

Table top air cleaner
Table of Contents

Advertisement

General Parts Replacement
EXTREME HIGH VOLTAGE WIRING WARNING - The unit has been designed
such that extremely high cell collector voltage wiring is isolated from all other
wiring. Special wiring routing holders have been designed into the unit. This
extremely high voltage wiring must be routed correctly. Failure to route and isolate
the wire can create a fire hazard, personal injury or property damage.
2. Carefully remove the ionizer needle
assembly that is the piece of red insulated
wire with fast on connection on one end
and the needle on the other end. Replace
with new needle assembly.
3. Reverse step 1 above to replace
assembly.

Fan Blade Removal and Replacement

1. Follow steps 1, 2, 3, and 6 of Motor Removal and Replacement.
ROTATING ELEMENT WARNING - Unit has a rotating blower wheel and cooling
fan to circulate air and keep the unit cool. When servicing the unit and repairing
the unit always insure that you keep objects and internal electrical wiring away
from the rotating elements. Failure to allow for proper clearance for rotating
members can cause electric shock, personal injury or property damage.
2. Remove fan with flathead screwdriver by
lightly prying the fan off of the motor shaft.
3. Replace the fan with the new fan and
insure that the new fan is installed on the
motor shaft with the metal locking collar
closest to the motor body. Press the fan
onto the shaft and allow about 1/4"
distance between the motor end bracket
and the fan hub. Spin the fan to ensure it
is clear of all objects.
4. Reverse above step 1 above to replace
the fan.
24
IONIZER NEEDLE
ASSEMBLY

Advertisement

Table of Contents
loading

Table of Contents