Sharp 21J-FG1RU Service Manual page 20

Hide thumbs Also See for 21J-FG1RU:
Table of Contents

Advertisement

21J-FG1RU
4. H-VCO, VIF-VCO & S-TRAP fo ADJUSTMENT
No.
Adjustment point
1
H-VCO ADJ
2
(I
C BUS
CONTROL)
(AUTO &
MANUAL ADJ)
2
VIF-VCO ADJ
(I
2
C BUS
CONTROL)
(AUTO &
MANUAL ADJ)
3
S-TRAP fo
ADJ
(I
2
C BUS
CONTROL)
(AUTO &
MANUAL ADJ)
Adjustment procedure/conditions
(MANUAL ADJ)
1) In No signal (RASTER) condition.
2) Go to service mode, choose service data V03.
3) Connect oscilloscope to IC801 pin11, adj V03 until
freq become 15.625 ± 0.15 KHz
(Auto Adj)
1) In No signal (RASTER) condition.
2) Go to service mode.
3) Choose service data V03, by pressing R/C Auto
(Hex C1) key, OSD will appear "OK" at screen.
4) If appear "NG" pls repeat step 3.
(Manual ADJ)
1) In No signal (RASTER) condition.
2) Go to service mode, choose service data V02.
3) Connect oscilloscope to IC801 pin2, adj V02 until
voltage become 2.5 ± 1 V.
(Auto Adj)
1) In No signal (RASTER) condition.
2) Go to service mode, choose service data V02.
3) Press the R/C Auto (Hex C1) key, OSD will appear
"OK" at screen.
4) If appear "NG" pls repeat step 3.
(Manual ADJ)
1) In No signal (RASTER) condition.
2) Go to service mode, choose service data V21.
3) Connect oscilloscope to TP 801, adj V21 until
voltage become Min (below 5 V).
4) After that pls adj service data V20 & V24 same as
"V21", V22 to "V21-1", V23 to "V21+2".
(Auto Adj)
1) In No signal (RASTER) condition.
2) Go to service mode, choose service data V21.
3) Press the R/C Auto (Hex C1) key, OSD will appear
"OK" at screen.
4) If appear "NG" pls repeat step 3.
3 – 17
Waveform and others
This adjustment must be done
after aging at least 3 minutes.