Bradford White 46392H Installation & Operating Manual page 3

Stainless steel indirect-fired water heater
Table of Contents

Advertisement

The maximum boiler water supply temperature to the indirect
heat exchanger must not exceed 240°F (115°C).
Improper water quality will reduce the expected life of the water
heater. Hard water, sediment, high or low PH and high levels of
chlorides in the domestic water should be avoided. Be sure that
PH value falls between 6 and 8 and dissolved chlorides are less
than 100 ppm. A filter must be used where sediment is greater
than 5 microns in size that is present in the water. A water
softening system is recommended for areas with hard water. In
areas where water quality is unknown, a qualified water
treatment expert should be consulted.
NOTICE: Damage to tanks caused by improper water quality is not
covered under warranty.
Insulation blankets are not required for this water heater. This
water heater meets or exceeds the ASHRAE/IES 90.1b standards
with respect to insulation and standby loss requirements.
TABLE OF CONTENTS
I- IMPORTANT INFORMATION.....................
II- SPECIFICATIONS.....................................
III- GENERAL INFORMATION.........................
IV- PRE-INSTALLATION.................................
V- WATER CONNECTIONS.............................
VI- ELECTRICAL CONNECTIONS....................
VII- OPERATING INSTRUCTIONS.....................
VIII- MAINTENANCE........................................
IX- TROUBLESHOOTING GUIDE.....................
X- PARTS LIST.............................................