Download Print this page

LG 47LE8500 Service Manual page 11

Led lcd tv
Hide thumbs Also See for 47LE8500:

Advertisement

4.3.4. Adj. Command (Protocol)
<Command Format>
LEN
- LEN: Number of Data Byte to be sent
- CMD: Command
- VAL: FOS Data value
- CS: Checksum of sent data
- A: Acknowledge
Ex) [Send: JA_00_DD] / [Ack: A_00_okDDX]
RS-232C Command used during auto-adj.
A
RS-232C COMMAND
[CMD
ID
DATA]
wb
00
00
Begin White Balance adj.
wb
00
10
Gain adj.(internal white pattern)
wb
00
1f
Gain adj. completed
wb
00
20
Offset adj.(internal white pattern)
wb
00
2f
Offset adj. completed
wb
00
ff
End White Balance adj.(Internal pattern disappears)
Ex) wb 00 00 -> Begin white balance auto-adj.
wb 00 10 -> Gain adj.
ja 00 ff -> Adj. data
jb 00 c0
...
...
wb 00 1f -> Gain adj. completed
*(wb 00 20(start), wb 00 2f(end)) -> Off-set adj.
wb 00 ff -> End white balance auto-adj.
Adj. Map
A
ITEM
Command
(lower case ASCII)
Cmd 1
Cool
R-Gain
j
G-Gain
j
B-Gain
j
R-Cut
G-Cut
B-Cut
Medium
R-Gain
j
G-Gain
j
B-Gain
j
R-Cut
G-Cut
B-Cut
Warm
R-Gain
j
G-Gain
j
B-Gain
j
R-Cut
G-Cut
Copyright © 2010 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
CS
CMD
VAL
Explanation
Data Range
(Hex.)
Cmd 2
Min
Max
g
00
C0
h
00
C0
i
00
C0
a
00
C0
b
00
C0
c
00
C0
d
00
C0
e
00
C0
f
00
C0
4.3.5. Adj. method
(1) Auto adj. method
1) Set TV in adj. mode using POWER ON key.
2) Zero calibrate probe then place it on the center of the
Display.
3) Connect Cable (RS-232C)
4) Select mode in adj. Program and begin adjustment.
5) When adj. is complete (OK Sing), check adj. status pre
mode. (Warm, Medium, Cool)
6) Remove probe and RS-232C cable to complete adj.
W/B Adj. must begin as start command "wb 00 00" , and
A
finish as end command "wb 00 ff", and Adj. offset if need.
(2) Manual adj. method
1) Set TV in Adj. mode using POWER ON
2) Zero Calibrate the probe of Color Analyzer, then place it
on the center of LCD module within 10cm of the surface.
3) Press ADJ key -> EZ adjust using adj. R/C -> 7. White-
Balance then press the cursor to the right (KEY
(When KEY(
be displayed)
4) One of R Gain / G Gain / B Gain should be fixed at 192,
and the rest will be lowered to meet the desired value.
5) Adj. is performed in COOL, MEDIUM, WARM 3 modes
of color temperature.
If internal pattern is not available, use RF input. In EZ
A
Adj. menu 7.White Balance, you can select one of 2
Test-pattern: ON, OFF. Default is inner(ON). By
selecting OFF, you can adjust using RF signal in 216
Gray pattern.
Adj. condition and cautionary items
A
Default
1) Lighting condition in surrounding area
(Decimal)
2) Probe location
3) Aging time
- 11 -
) is pressed 216 Gray internal pattern will
G
Surrounding lighting should be lower 10 lux. Try to
isolate adj. area into dark surrounding.
: Color Analyzer (CA-210) probe should be within 10
cm and perpendicular of the module surface (80° ~
100°)
- After Aging Start, Keep the Power ON status during
5 Minutes.
- In case of LCD, Back-light on should be checked
using no signal or Full-white pattern.
).
G
LGE Internal Use Only

Hide quick links:

Advertisement

loading