Best iQ6 Installation Manual

Internal blower range hood system
Table of Contents

Advertisement

Available languages

Available languages

INTERNAL
BLOWER
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
personnel in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting.Follow the heating equipment
manufacturer's guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this range hood with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
For use with compatible BEST
See hood manual for suitability.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE
EVENT OF A RANGE TOP GREASE FIRE,OBSERVE THE
FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels – This
could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This blower has a thermal overload which will automatically
shut off the motor if it becomes overheated.The motor will
restart when it cools down.If the motor continues to shut off
and restart, have the hood serviced.
4. Please read specification label on product for further
information and requirements.
5. To reduce the risk of fire and to properly exhaust air on a ducted
installation, be sure to duct air outside – Do not exhaust air
into spaces within walls or ceiling or into attics, crawl spaces,
or garage.
Save this manual for Electrical Inspector
®
range hoods.
!
INSTALLER:
and Homeowner to use.
MODEL iQ6
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iQ6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Best iQ6

  • Page 1 MODEL iQ6 Page 1 INTERNAL ® For use with compatible BEST range hoods. BLOWER See hood manual for suitability. WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE...
  • Page 2 MODEL iQ6 Page 2 MODEL 643 MODEL 634 OR 644 (8’’ Round wall cap) (roof cap) Wall & Roof Caps, Exterior Blowers MODEL 432 Elbows (8” round adjustable elbow) MODEL 408 Ductwork (8” round duct) (8” Damper - included) MODEL iQ6...
  • Page 3: Installation

    MODEL iQ6 Page 3 INSTALLATION VERTICAL DISCHARGE REMOVE ONE (UP26M, UP27M, WP28M, WP29M, IP29M) ELECTRICAL KNOCKOUT Run power cable to installation location. Remove one electrical knockout from rough in plate wiring box. HORIZONTAL DISCHARGE (WP28, WP29) Attach rough in plate to mounting studs at inside of hood...
  • Page 4 MODEL iQ6 Page 4 CALIBRATE iQ BLOWER ROUGH-IN PLATE SYSTEM BLACK TO BLACK GROUND WIRE TO GROUND WHITE TO WHITE SCREW INTERNAL BLOWER DUCTED UNITS ONLY After the hood is installed and wired, engage the calibration process (our Guaranteed Performance System Technology to ensure full-rated airflow is being delivered).
  • Page 5: Service Parts

    PCB ENCLOSURE KIT (INCLUDES KEYS 9-11) SCREW, 3MM X 6MM PH W/LOCK WASHER IQ6 PCB BOARD 97019458 IQ6 PCB BOARD KIT (INCLUDES KEY 12 AND KEY 13) PCB TRIAC BOARD STANDOFF 97019471 PCB TRIAC BOARD KIT (INCLUDES KEY 14 AND 15)
  • Page 6 MODÈLE iQ6 Page 6 VENTILATEUR ® Pour utilisation avec les hottes de cuisine BEST compatibles. INTERNE Voir dans le manuel de la hotte si le modèle convient. AVERTISSEMENT AVERTISSEMENT A F I N D E D I M I N U E R L E S R I S Q U E S D ’ I N C E N D I E , OBSERVEZ LES CONSIGNES SUIVANTES AFIN DE RÉDUIRE...
  • Page 7 MODÈLE iQ6 Page 7 MODÈLE 643 MODÈLE 634 OU 644 (capuchon mural rond (capuchon de toit) de 20 cm [8 po]) Capuchon mural et de toit, ventilateurs extérieurs MODÈLE 432 Coudes (coude rond ajustable de 20 cm [8 po]) MODÈLE 408...
  • Page 8 MODÈLE iQ6 Page 8 INSTALLATION ÉVACUATION VERTICALE RETIREZ UNE RONDELLE (UP26M, UP27M, WP28M, WP29M, IP29M) DÉTACHABLE POUR LE CÂBLE ÉLECTRIQUE. Acheminez un câble à trois fils jusqu’au lieu d’installation. Enlevez la rondelle détachable de la plaque de raccordement du boîtier de câblage.
  • Page 9 MODÈLE iQ6 Page 9 CALIBRAGE DU PLAQUE DE RACCORDEMENT VENTILATEUR iQ NOIR AVEC NOIR FIL DE TERRE SUR LA VIS DE BLANC AVEC BLANC MISE À LA TERRE VENTILATEUR INTERNE AVEC CONDUITS SEULEMENT Une fois la hotte installée et connectée, enclenchez le processus de calibrage (notre Technologie de performance garantie s’assure que le débit d’air optimal sera émis).
  • Page 10: Pièces De Rechange

    ENS. DE BOÎTIER PCB (COMPREND PIÈCES 9-11) VIS, 3MM X 6MM PH AVEC RONDELLE DE BLOCAGE CIRCUIT PCB IQ6 97019458 ENS. DE CIRCUIT PCB IQ6 (COMPREND 12 ET 13) CIRCUIT PCB TRIAC TAQUET 97019471 ENS. DE CIRCUIT PCB TRIAC (COMPREND 14 ET 15)
  • Page 11 MODELO iQ6 Página 11 VENTILADOR ® Para usarse con campanas de estufa compatibles de BEST INTERNO Consulte el manual de la campana para su idoneidad. ADVERTENCIA ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA PARA REDUCIR EL RIESGO DE LESIONES PERSONALES EN ELÉCTRICA O LESIONES PERSONALES, OBSERVE...
  • Page 12 MODELO iQ6 Página 12 MODELO 643 MODELO 634 O 644 (tapa redonda de 8 pulg. (tapa de techo) [20 cm] para pared) Tapas de pared y techo, ventiladores exteriores MODELO 432 Codos (codo redondo ajustable de 8 pulg. [20 cm])
  • Page 13: Instalación

    MODELO iQ6 Página 13 INSTALACIÓN DESCARGA VERTICAL RETIRE UN (UP26M, UP27M, WP28M, WP29M, IP29M) AGUJERO CIEGO ELÉCTRICO Haga pasar el cable eléctrico al sitio de la instalación. Retire un agujero ciego eléctrico de la caja de cableado de la caja de empalme.
  • Page 14 MODELO iQ6 Página 14 CALIBRACIÓN DEL PLACA DE EMPALME VENTILADOR iQ NEGRO CON NEGRO CABLE DE TIERRA A TORNILLO DE BLANCO CON BLANCO PUESTA A TIERRA SOLO UNIDADES CON CONDUCTOS DE VENTILADOR INTERNO Después de instalar y cablear la campana, active el proceso de calibración (nuestra tecnología de sistema...
  • Page 15: Piezas De Servicio

    JUEGO DE CAJA PCB (INCLUYE LAS CLAVES 9-11) TORNILLO, 3 MM X 6 MM PH CON ARANDELA DE SEGURIDAD TABLERO PCB, IQ6 97019458 JUEGO DE TABLERO PCB IQ6 (INCLUYE LAS CLAVES 12 Y 13) TABLERO TRIAC PCB SEPARADOR 97019471 JUEGO DE TABLERO TRIAC...
  • Page 16: Warranty / Garantie / Garantía

    GARANTIE LIMITÉE D’UN AN DES PRODUITS BEST Broan-NuTone LLC (Broan-NuTone) garantit à l’acheteur original que les produits Best sont libres de tout vice de matériau ou de fabrication pour une période d’un an à compter de la date d’achat originale. CETTE GARANTIE NE COMPORTE AUCUNE AUTRE GARANTIE, EXPRESSE OU TACITE, Y COMPRIS, MAIS SANS S’Y LIMITER, LES GARANTIES TACITES DE VALEUR MARCHANDE OU D’ADAPTATION À...

Table of Contents