COPYRIGHT AND TRADEMARKS All rights reserved by C&C TECHNIC TAIWAN CO., LTD. No part of this document may be reproduced in any form or by any means without written permission from the product manufacturer. Changes are periodically made to the information in this document. They will be incorporated in subsequent editions.
BEFORE YOU BEGIN Follow all instructions marked on the device during using. Provide proper ventilation and air circulation and do not use near water. It is better to keep it in a dry environment. Place the device on a stable surface (example cart, stand, table, etc.). ...
Page 5
7.3.2 LAN Main Operation ..................34 7.3.4 LAN IP Function.................... 36 7.3.5 Other Application................... 37 Chapter 8 Troubleshooting....................38 Appendix A IR Controller....................... 40 Appendix B Firmware Upgrade .................... 42 Appendix C RS-232 Communication Protocol..............45 D-1 Host Request......................45 D-1.1 Device Byte ....................
Through a standard TCP/IP connection with seamless integration in any existing network for easy remote access. With easy operation, the HRM-602P allows you to use both pushbuttons and IR remote control to operate the device.
CHAPTER 3 SPECIFICATIONS Hardware Input Connector 6 x HDMI Type A Female Output Connector 1 x HDMI Type A Female, 1 x VGA HD15 Female RS-232 Connector 1 x DB9 Female LAN Connector 1 x RJ-45 Audio Port 1 x Audio Out Port 8 pins Dip Switcher 16 x LED indicators specified for the connection is LED Indicators...
5.1 Front Panel Figure 5-1 HRM-602P Switcher Front Panel The HRM-602P Switcher supports up to 12 switching keys on the Front Panel for indicating the connection status of the Main or Slave window that allows you to switch each screen quickly.
Page 11
Only one of input channel can be configured as output source. Audio Delay: The HRM-602P Switcher supports you 0, 10, 20, 30, 40, 50, 70 and 70 ms audio delay settings. Usually, when you process the video images, at times, it can take longer than processing the audio signal.
Page 12
PIP feature, one in the main screen and the other in the slave window. The HRM-602P Switcher supports you up to 7 display modes as below: 6 display modes for the full aspect: (for reference)
Page 13
6 display modes for the actual aspect: (for reference) Figure 5-5 Display Modes for Actual Aspect(4:3 video output to 16:9) Normal Mode: Only the main channel will be displayed – No PIP displays. PIP Mode: Shows you two channels simultaneously. Each of them is assigned to Main or Slave window individually.
Page 14
For PBP Mode, you have to adjust the PIP Mode located on the front panel of HRM-602P Switcher to No. 5 or 6/7. The PIP Mode No.7 is the same as No.6. Figure 5-6 PIP Display for PBP Mode 5...
IR: Infrared receiver for the HRM-602P Switcher. The longest distance of your IR remote controller to receive the signals is about 12 meters. Figure 5-8 IR Receiving Distance 5.2 IR Remote Controller Figure 5-9 IR Remote Controller Main Channel Port selection: Press the Number#1~6 button to select the channel to the Main channel.
5.3 Rear Panel Figure 5-10 HRM-602P Switcher Rear Panel The HRM-602P Switcher supports up to 6 input and 1 output jacks (HDMI Type A) on the rear panel, each female terminals separately form the signal input and output jacks. The signal input connector are numbered as “HDMI1~6”...
Page 17
Connection. Figure 5-11 IR Receiver Pin Definition LAN Port: Use the RJ-45 connection cable to connect the Internet and the HRM-602P Switcher. The entire PC at the same network can control the HRM-602P Switcher through the LAN port. Refer to 6.5.2 LAN...
CHAPTER 6 CONNECTIONS Figure 6-1 HRM-602P Connections 6.1 Input/Output Connections Use the HDMI connecting cable to connect the Input HDMI connector (HDMI 1 ~ HDMI 6) to the HDMI connector of the CD/DVD player/Camera/PS3/STB/PC and output connector (HDMI OUT) to the HDMI connector of the HDMI TV, displays, multiplexers and so on.
RS-232 connection port for a remote operation. Figure 6-4 RS-232 and Control PC connection The HRM-602P Switcher also supports a LAN port allows you to control all the series connection devices through PC Browser.
6.3 IR EXT Connection The HRM-602P Switcher provides you an IR receiver for more convenient to react to the controller. If it is difficult for you to aim at IR receiver on the front panel due to the location of Switcher, please connect it to the IR EXT port located on the rear panel for optional position.
6.5 Ports and Switchers The HRM-602P Switcher provides standard RS-232 serial communication port. Beside the front panel for key switching operation, you can also use the RS-232 serial communication port to carry out remote operation. 6.5.1 RS-232 The RS-232 Pin functions are described as below: Pin No.
Page 22
Figure 6-8 (b) Figure 6-9 The Switcher RS-232 port is defined by DCE.
2. After the HRM-602P Switcher re-starts about 10 seconds, shut down your equipment. 3. For a normal operation, please adjust the pin1 to OFF, then power on the HRM-602P Switcher again. The IP address will be restored to the default value: 192.168.0.3...
B. DIP Switcher Pin 2 to 3: Switch between RS-232 port and LAN port connection. RS-232 C. DIP Switcher Pin 4 to 8: Switch to down (ON) is specified for “0”, on the other hand to up (OFF) is specified for “1”. 6.5.4 Device ID Settings Device ID Settings The Device ID determines the position of a Selector system.
CHAPTER 7 SWITCHER APPLICATION SOFTWARE 7.1 Software Introduction The 《AV Matrix》 matrix control software applies to different input/output matrixes. 7.1.1 Software Description The 《AV Matrix》 matrix testing software is an application tool developed for matrix testing and application. The software operation environment is as below: Window98/2000/NT/XP operating systems 32M internal memory or above 10M hard disk space or above...
7.1.3 Connect HRM-602P and PC You must power off the HRM-602P Switcher. Then, connect the Switcher RS-232 port to the PC RS-232 port with the bundled communication cable. And make sure the DIPs on the rear panel are set to Master and RS-232. (Refer to the previous section 6.5.1...
Examples for selecting switching functions: Example: Now there is an HRM-602P Switcher having all the input/output ports properly connected to the equipment. If you want to set channel 1 input to channel 2, 3 and 4 output;...
Page 29
Upon completion of the above steps, you have actually completed the switching operation of having channel 1 input to channel 2, 3 and 4 outputs while at the same time successfully switched from channel 3 input to channel 1 output. The main configuration window also shows you some function buttons to easy operation: Switch Tab: Click “Switch”...
7.2.2 Disconnect Function Key Disable all the unused output ports. A specific example of operation is described as below: The present input and output relations are shown in Figure 7-4 (a) below: Figure 7-4 Disconnect Function Key (a)
7.2.3 Options Function Activation Function: In the main configuration menu, select Options to prop-up the Options Window as shown in Figure 7-5(a) Figure 7-5 Options(a) Figure 7-5 Options(b) Function Description: Linking Methods: In “Port number” select one of the COM ports as shown in Figure 7-5(b)for a example;...
The LAN main configuration window is as below: Figure 7-6 LAN Web Configuration Window HRM-602P Switcher is integrated HDMI switching equipment. You can only key in the Output Channel No. into the Video field for configuration.
Page 33
AV Link: Link between audio and video. Key In: A Hot key that is for key in the value 0~99 quickly. After setting the value, click “Enable” to take effect. For HRM-602P Switcher is useful from 1 to 16 values upon 16 output ports.
7.3.1 Video Configuration For video configuration, click Video button directly to pop-up “Video Settings” window. Figure 7-8 Video Operation In “Video Settings” window, you can click Change button to switch EDID Output1 and Default port. Figure 7-9 Video Configurations – Default port used ...
Output 1 is Main channel of the HRM-602P. Output 2 is Slave channel of the HRM-602P. Example: Now there is an HRM-602P Switcher having all the input/output ports properly connected to the equipment. If you want to set channel 4 input to output 1; channel 3 inputs to output 2.
Page 36
Step 1: For channel 1 Output, please key in the value “4” in the Video fields. Step 2: For channel 2 Output, please key in the value “3” in the Vide fields. Step 3: Click “Set” button. Upon completion of the above 3 steps, you have actually completed the switching operation of having channel 4 input to channel 1 output while at the same time successfully switched from channel 3 input to channel 2 output.
7.3.4 LAN IP Function In the main configuration menu, select Options button to prop-up the Browser ex. “Windows Internet Explorer” dialog box, click “OK” to show the IP configuration window as shown in Figure 7-14 Figure 7-14 Network Settings In the “Network Settings” window, you can set the IP information by yourself (Fix IP) or click the Enable DHCP check box to get the IP from the DHCP (Float IP).
For this model, the software utility will show at least 1 up to 32 devices. The example as below shows you an ID: 0 for the Name: HRM-602P Switcher presently. When the Console List is empty, please pay attention to the location of switcher pin on the rear panel of Device is correctly.
CHAPTER 8 TROUBLESHOOTING 1. What to do if LCD is fail in display? Answer: Check the connection of power cord is not loosening and the power cord is in a good status having no any damage. Check the power source is normally. 2.
Page 40
5. What to do if you sense the power leakage during plugging or unplugging of the input/output ports? Answer: It could be that the equipment power is not properly grounded. You must properly ground your equipment; otherwise product life can easily be shortened. 6.
APPENDIX A IR CONTROLLER The HRM-602P Switcher supports a remote controller allows you to remote switch which Input signal by passing through to current output with an extended connection - IR receiver/transmitter. The signal for controller is only available to the IR receiver connected to the IR hole located on the rear panel.
Page 42
Example: Press the “0” button on the Remote controller first, then press the “3” button to select the channel#3 input signal to the Slave channel. (Only available with PIP mode 1~7).
APPENDIX B FIRMWARE UPGRADE This Chapter will introduce you how to upgrade firmware on your web browser. For firmware upgrade, you have to upload the firmware file to your web server and then upload it to your device from web server. Follow the steps as below to upgrade the firmware: 1.
Page 44
For 0: General selecting, you have to adjust the switcher ID on the real panel to “0” that means the device with ID “0” will be upgraded. 4. For 1: Switcher Device will allow you to select target device based on ID 0 to 31 for upgrading firmware.
Page 45
6. After finishing firmware upgrade successfully, “Firmware Upgrade to Device Success” information will appear as below. Besides, the firmware upgrade will not stop even though the web connection is fail suddenly. Please check with the LCD screen to confirm the firmware upgrade has been finished successfully or wait at least 2 minutes then power off to restart your 7.
APPENDIX C RS-232 COMMUNICATION PROTOCOL This AV Matrix RS-232 communication protocol uses fixed length with 5 bytes of information as define below. The default baud rate is 9600 bps, no parity, 8 data bit and 1 stop bit. Command timeout is 300 ms, and byte to byte timeout is 30ms. Use the RS-232 connecting cable to connect the computer serial port to the RS-232 communication port of the Switcher device.
1: Identifier, Always 1. Device ID: Device id ranges from 0 to 31. (Please refer to device’s user manual) D-1.2 Request Byte Request Byte (RB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Request Type (0 - 63) Request Type: Please refer to "Table - Host Request List".
D-1.3 Index Byte Index Byte (IB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Index Index: Please refer to "Table - Host Request List" and "Table - Command Index List". Table – Command Index List Index Description The output that will be selected.
D-1.4 Value Byte Value Byte (VB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Value Value: Please refer to "Table - Host Request List" and "Table - Command Value List". Table – Command Value List Value Description The input that will be connected.
D-1.5 CRC Byte CRC Byte (CB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 CRC (cyclic redundancy check) CRC: Host must send CRC code to follow the last byte. Table – CRC Table BC E2 DD 83 C2 9C...
D-2.2 ACK Type B ACK Byte + LB + Index1 + Value1 + Index2 + Value2 +…..+ CRC Byte Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 – 31) Length for the total data bytes (Index + Value) IB n Index...
D-2.3 ACK Type C ACK Byte + LB + Data 1 + Data 2 + CRC Byte (Total 5 Bytes) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 – 31) Length for the total data bytes (This byte is always 2) DB 1 Data 1...
D-2.4 ACK Type D ACK Byte + LB + INF + OP + IP + Name 1 + Name 2 + Name 3 +..+ CRC Byte Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 - 31) Length for the total data bytes (INFO +..+ Name n)
D-2.5 ACK Type E ACK Byte + LB + EXTI + VIDI + AUDI + PLUG +..+ CRC Byte Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 - 31) Length for the total data bytes (EXINF +..+ DTMAX) LBMAX EXINF...
Page 57
BASS - Bass command flag. (Request 0x14 and 0x15) 1 - Support Bass command. 0 - Not support Bass command. TRE - Treble command flag. (Request 0x16 and 0x17) 1 - Support Treble command. 0 - Not support Treble command. SW - Subwoofer command flag.
Need help?
Do you have a question about the HRM-602P and is the answer not in the manual?
Questions and answers