User Manual

Seamless HDMI Switch Scaler
with PIP and Audio Delay Functionality
6x2
HRM-602P
V.2013HRM-602P.00
0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HRM-602P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AVLink HRM-602P

  • Page 1: User Manual

    User Manual Seamless HDMI Switch Scaler with PIP and Audio Delay Functionality HRM-602P V.2013HRM-602P.00...
  • Page 2: Copyright And Trademarks

    COPYRIGHT AND TRADEMARKS All rights reserved by C&C TECHNIC TAIWAN CO., LTD. No part of this document may be reproduced in any form or by any means without written permission from the product manufacturer. Changes are periodically made to the information in this document. They will be incorporated in subsequent editions.
  • Page 3: Before You Begin

    BEFORE YOU BEGIN  Follow all instructions marked on the device during using.  Provide proper ventilation and air circulation and do not use near water.  It is better to keep it in a dry environment.  Place the device on a stable surface (example cart, stand, table, etc.). ...
  • Page 4: Table Of Contents

    Chapter 7 Switcher Application Software ................25 7.1 Software Introduction ....................25 7.1.1 Software Description ..................25 7.1.2 Software Activation ..................25 7.1.3 Connect HRM-602P and PC................ 26 7.2 Switcher Configuration .................... 26 7.2.1 Main Operation Interface................27 7.2.2 Disconnect Function Key ................29 7.2.3 Options Function...................
  • Page 5 7.3.2 LAN Main Operation ..................34 7.3.4 LAN IP Function.................... 36 7.3.5 Other Application................... 37 Chapter 8 Troubleshooting....................38 Appendix A IR Controller....................... 40 Appendix B Firmware Upgrade .................... 42 Appendix C RS-232 Communication Protocol..............45 D-1 Host Request......................45 D-1.1 Device Byte ....................
  • Page 6: Chapter 1 Switcher System Overview

    Through a standard TCP/IP connection with seamless integration in any existing network for easy remote access. With easy operation, the HRM-602P allows you to use both pushbuttons and IR remote control to operate the device.
  • Page 7: Packing

    1.2 Packing HRM-602P Switcher *1 RS-232 Communication Connected Cable *1 Power Cord *1 Adapter *1 HDMI Cable *1 Rack-Mount Bracket *2 Screws (for Brackets) *6 IR Remote Controller *1 Software CD *1 (Includes “AV Matrix Control Software” and “User Manual”)
  • Page 8: Chapter 2 Features

    CHAPTER 2 FEATURES Up/down/cross converter equipped with HDMI input/output.  - Supports interlaced video to progressive video. (like 1080i => 1080P) - Supports up convert. (like VGA => 1080P@60) - Supports down convert. (like 1080P@60 => VGA) - Supports cross convert. (like 576i@50 => 1080P@60) HDTV resolution up to 1080p.
  • Page 9: Chapter 3 Specifications

    CHAPTER 3 SPECIFICATIONS Hardware Input Connector 6 x HDMI Type A Female Output Connector 1 x HDMI Type A Female, 1 x VGA HD15 Female RS-232 Connector 1 x DB9 Female LAN Connector 1 x RJ-45 Audio Port 1 x Audio Out Port 8 pins Dip Switcher 16 x LED indicators specified for the connection is LED Indicators...
  • Page 10: Chapter 4 Device Installation

    5.1 Front Panel Figure 5-1 HRM-602P Switcher Front Panel The HRM-602P Switcher supports up to 12 switching keys on the Front Panel for indicating the connection status of the Main or Slave window that allows you to switch each screen quickly.
  • Page 11  Only one of input channel can be configured as output source.  Audio Delay: The HRM-602P Switcher supports you 0, 10, 20, 30, 40, 50, 70 and 70 ms audio delay settings. Usually, when you process the video images, at times, it can take longer than processing the audio signal.
  • Page 12 PIP feature, one in the main screen and the other in the slave window.  The HRM-602P Switcher supports you up to 7 display modes as below:  6 display modes for the full aspect: (for reference)
  • Page 13  6 display modes for the actual aspect: (for reference) Figure 5-5 Display Modes for Actual Aspect(4:3 video output to 16:9) Normal Mode: Only the main channel will be displayed – No PIP displays. PIP Mode: Shows you two channels simultaneously. Each of them is assigned to Main or Slave window individually.
  • Page 14  For PBP Mode, you have to adjust the PIP Mode located on the front panel of HRM-602P Switcher to No. 5 or 6/7. The PIP Mode No.7 is the same as No.6. Figure 5-6 PIP Display for PBP Mode 5...
  • Page 15: Ir Remote Controller

     IR: Infrared receiver for the HRM-602P Switcher. The longest distance of your IR remote controller to receive the signals is about 12 meters. Figure 5-8 IR Receiving Distance 5.2 IR Remote Controller Figure 5-9 IR Remote Controller Main Channel Port selection: Press the Number#1~6 button to select the channel to the Main channel.
  • Page 16: Rear Panel

    5.3 Rear Panel Figure 5-10 HRM-602P Switcher Rear Panel The HRM-602P Switcher supports up to 6 input and 1 output jacks (HDMI Type A) on the rear panel, each female terminals separately form the signal input and output jacks. The signal input connector are numbered as “HDMI1~6”...
  • Page 17 Connection. Figure 5-11 IR Receiver Pin Definition  LAN Port: Use the RJ-45 connection cable to connect the Internet and the HRM-602P Switcher. The entire PC at the same network can control the HRM-602P Switcher through the LAN port. Refer to 6.5.2 LAN...
  • Page 18: Chapter 6 Connections

    CHAPTER 6 CONNECTIONS Figure 6-1 HRM-602P Connections 6.1 Input/Output Connections Use the HDMI connecting cable to connect the Input HDMI connector (HDMI 1 ~ HDMI 6) to the HDMI connector of the CD/DVD player/Camera/PS3/STB/PC and output connector (HDMI OUT) to the HDMI connector of the HDMI TV, displays, multiplexers and so on.
  • Page 19: Hdmi Switcher System Remote Control

    RS-232 connection port for a remote operation. Figure 6-4 RS-232 and Control PC connection The HRM-602P Switcher also supports a LAN port allows you to control all the series connection devices through PC Browser.
  • Page 20: Ir Ext Connection

    6.3 IR EXT Connection The HRM-602P Switcher provides you an IR receiver for more convenient to react to the controller. If it is difficult for you to aim at IR receiver on the front panel due to the location of Switcher, please connect it to the IR EXT port located on the rear panel for optional position.
  • Page 21: Ports And Switchers

    6.5 Ports and Switchers The HRM-602P Switcher provides standard RS-232 serial communication port. Beside the front panel for key switching operation, you can also use the RS-232 serial communication port to carry out remote operation. 6.5.1 RS-232 The RS-232 Pin functions are described as below: Pin No.
  • Page 22 Figure 6-8 (b) Figure 6-9  The Switcher RS-232 port is defined by DCE.
  • Page 23: Lan Port

    2. After the HRM-602P Switcher re-starts about 10 seconds, shut down your equipment. 3. For a normal operation, please adjust the pin1 to OFF, then power on the HRM-602P Switcher again. The IP address will be restored to the default value: 192.168.0.3...
  • Page 24: Device Id Settings

    B. DIP Switcher Pin 2 to 3: Switch between RS-232 port and LAN port connection. RS-232 C. DIP Switcher Pin 4 to 8: Switch to down (ON) is specified for “0”, on the other hand to up (OFF) is specified for “1”. 6.5.4 Device ID Settings Device ID Settings The Device ID determines the position of a Selector system.
  • Page 25 10000 10001 10010 10011 10100 10101 10110 10111 11000 11001 11010 11011 11100 11101 11110 11111...
  • Page 26: Chapter 7 Switcher Application Software

    CHAPTER 7 SWITCHER APPLICATION SOFTWARE 7.1 Software Introduction The 《AV Matrix》 matrix control software applies to different input/output matrixes. 7.1.1 Software Description The 《AV Matrix》 matrix testing software is an application tool developed for matrix testing and application. The software operation environment is as below: Window98/2000/NT/XP operating systems 32M internal memory or above 10M hard disk space or above...
  • Page 27: Connect Hrm-602P And Pc

    7.1.3 Connect HRM-602P and PC You must power off the HRM-602P Switcher. Then, connect the Switcher RS-232 port to the PC RS-232 port with the bundled communication cable. And make sure the DIPs on the rear panel are set to Master and RS-232. (Refer to the previous section 6.5.1...
  • Page 28: Main Operation Interface

    Examples for selecting switching functions: Example: Now there is an HRM-602P Switcher having all the input/output ports properly connected to the equipment. If you want to set channel 1 input to channel 2, 3 and 4 output;...
  • Page 29 Upon completion of the above steps, you have actually completed the switching operation of having channel 1 input to channel 2, 3 and 4 outputs while at the same time successfully switched from channel 3 input to channel 1 output. The main configuration window also shows you some function buttons to easy operation: Switch Tab: Click “Switch”...
  • Page 30: Disconnect Function Key

    7.2.2 Disconnect Function Key Disable all the unused output ports. A specific example of operation is described as below: The present input and output relations are shown in Figure 7-4 (a) below: Figure 7-4 Disconnect Function Key (a)
  • Page 31: Options Function

    7.2.3 Options Function Activation Function: In the main configuration menu, select Options to prop-up the Options Window as shown in Figure 7-5(a) Figure 7-5 Options(a) Figure 7-5 Options(b) Function Description: Linking Methods: In “Port number” select one of the COM ports as shown in Figure 7-5(b)for a example;...
  • Page 32: Lan Web Configuration

    The LAN main configuration window is as below: Figure 7-6 LAN Web Configuration Window  HRM-602P Switcher is integrated HDMI switching equipment. You can only key in the Output Channel No. into the Video field for configuration.
  • Page 33 AV Link: Link between audio and video. Key In: A Hot key that is for key in the value 0~99 quickly. After setting the value, click “Enable” to take effect. For HRM-602P Switcher is useful from 1 to 16 values upon 16 output ports.
  • Page 34: Video Configuration

    7.3.1 Video Configuration For video configuration, click Video button directly to pop-up “Video Settings” window. Figure 7-8 Video Operation In “Video Settings” window, you can click Change button to switch EDID Output1 and Default port. Figure 7-9 Video Configurations – Default port used ...
  • Page 35: Lan Main Operation

    Output 1 is Main channel of the HRM-602P. Output 2 is Slave channel of the HRM-602P. Example: Now there is an HRM-602P Switcher having all the input/output ports properly connected to the equipment. If you want to set channel 4 input to output 1; channel 3 inputs to output 2.
  • Page 36 Step 1: For channel 1 Output, please key in the value “4” in the Video fields. Step 2: For channel 2 Output, please key in the value “3” in the Vide fields. Step 3: Click “Set” button. Upon completion of the above 3 steps, you have actually completed the switching operation of having channel 4 input to channel 1 output while at the same time successfully switched from channel 3 input to channel 2 output.
  • Page 37: Lan Ip Function

    7.3.4 LAN IP Function In the main configuration menu, select Options button to prop-up the Browser ex. “Windows Internet Explorer” dialog box, click “OK” to show the IP configuration window as shown in Figure 7-14 Figure 7-14 Network Settings In the “Network Settings” window, you can set the IP information by yourself (Fix IP) or click the Enable DHCP check box to get the IP from the DHCP (Float IP).
  • Page 38: Other Application

    For this model, the software utility will show at least 1 up to 32 devices. The example as below shows you an ID: 0 for the Name: HRM-602P Switcher presently.  When the Console List is empty, please pay attention to the location of switcher pin on the rear panel of Device is correctly.
  • Page 39: Chapter 8 Troubleshooting

    CHAPTER 8 TROUBLESHOOTING 1. What to do if LCD is fail in display? Answer: Check the connection of power cord is not loosening and the power cord is in a good status having no any damage. Check the power source is normally. 2.
  • Page 40 5. What to do if you sense the power leakage during plugging or unplugging of the input/output ports? Answer: It could be that the equipment power is not properly grounded. You must properly ground your equipment; otherwise product life can easily be shortened. 6.
  • Page 41: Appendix A Ir Controller

    APPENDIX A IR CONTROLLER The HRM-602P Switcher supports a remote controller allows you to remote switch which Input signal by passing through to current output with an extended connection - IR receiver/transmitter. The signal for controller is only available to the IR receiver connected to the IR hole located on the rear panel.
  • Page 42 Example: Press the “0” button on the Remote controller first, then press the “3” button to select the channel#3 input signal to the Slave channel. (Only available with PIP mode 1~7).
  • Page 43: Appendix B Firmware Upgrade

    APPENDIX B FIRMWARE UPGRADE This Chapter will introduce you how to upgrade firmware on your web browser. For firmware upgrade, you have to upload the firmware file to your web server and then upload it to your device from web server. Follow the steps as below to upgrade the firmware: 1.
  • Page 44  For 0: General selecting, you have to adjust the switcher ID on the real panel to “0” that means the device with ID “0” will be upgraded. 4. For 1: Switcher Device will allow you to select target device based on ID 0 to 31 for upgrading firmware.
  • Page 45 6. After finishing firmware upgrade successfully, “Firmware Upgrade to Device Success” information will appear as below. Besides, the firmware upgrade will not stop even though the web connection is fail suddenly. Please check with the LCD screen to confirm the firmware upgrade has been finished successfully or wait at least 2 minutes then power off to restart your 7.
  • Page 46: Appendix C Rs-232 Communication Protocol

    APPENDIX C RS-232 COMMUNICATION PROTOCOL This AV Matrix RS-232 communication protocol uses fixed length with 5 bytes of information as define below. The default baud rate is 9600 bps, no parity, 8 data bit and 1 stop bit. Command timeout is 300 ms, and byte to byte timeout is 30ms. Use the RS-232 connecting cable to connect the computer serial port to the RS-232 communication port of the Switcher device.
  • Page 47: D-1.2 Request Byte

    1: Identifier, Always 1. Device ID: Device id ranges from 0 to 31. (Please refer to device’s user manual) D-1.2 Request Byte Request Byte (RB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Request Type (0 - 63) Request Type: Please refer to "Table - Host Request List".
  • Page 48 0x13 Request Audio Output Volume Output Memory 0x14 Control Audio Output Bass Output Level 0x15 Request Audio Output Bass Output Memory 0x16 Control Audio Output Treble Output Level 0x17 Request Audio Output Treble Output Memory 0x18 Control Audio Output Subwoofer Output Level 0x19...
  • Page 49: D-1.3 Index Byte

    D-1.3 Index Byte Index Byte (IB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Index Index: Please refer to "Table - Host Request List" and "Table - Command Index List". Table – Command Index List Index Description The output that will be selected.
  • Page 50: D-1.4 Value Byte

    D-1.4 Value Byte Value Byte (VB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Value Value: Please refer to "Table - Host Request List" and "Table - Command Value List". Table – Command Value List Value Description The input that will be connected.
  • Page 51: D-1.5 Crc Byte

    D-1.5 CRC Byte CRC Byte (CB) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 CRC (cyclic redundancy check) CRC: Host must send CRC code to follow the last byte. Table – CRC Table BC E2 DD 83 C2 9C...
  • Page 52: Device Ack Packet

    CRC Calculation CRC 0 = 0 (initial value) CRC 1 = CRC_ TABLE [CRC 0 ^ Byte 1] = CRC_ TABLE [0x00 ^ 0x20] = 0x23 CRC 2 = CRC_ TABLE [CRC 1 ^ Byte 2] = CRC_ TABLE [0x23 ^ 0x01] = 0x9F CRC 3 = CRC_ TABLE [CRC 2 ^ Byte 3] = CRC_ TABLE [0x9F ^ 0x06] = 0x8D CRC 4 = CRC_ TABLE [CRC 3 ^ Byte 4] = CRC_ TABLE [0x8D ^ 0x03] = 0x93 D-2 Device ACK Packet...
  • Page 53: D-2.2 Ack Type B

    D-2.2 ACK Type B ACK Byte + LB + Index1 + Value1 + Index2 + Value2 +…..+ CRC Byte Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 – 31) Length for the total data bytes (Index + Value) IB n Index...
  • Page 54: D-2.3 Ack Type C

    D-2.3 ACK Type C ACK Byte + LB + Data 1 + Data 2 + CRC Byte (Total 5 Bytes) Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 – 31) Length for the total data bytes (This byte is always 2) DB 1 Data 1...
  • Page 55: D-2.4 Ack Type D

    D-2.4 ACK Type D ACK Byte + LB + INF + OP + IP + Name 1 + Name 2 + Name 3 +..+ CRC Byte Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 - 31) Length for the total data bytes (INFO +..+ Name n)
  • Page 56: D-2.5 Ack Type E

    D-2.5 ACK Type E ACK Byte + LB + EXTI + VIDI + AUDI + PLUG +..+ CRC Byte Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 - 31) Length for the total data bytes (EXINF +..+ DTMAX) LBMAX EXINF...
  • Page 57 BASS - Bass command flag. (Request 0x14 and 0x15) 1 - Support Bass command. 0 - Not support Bass command. TRE - Treble command flag. (Request 0x16 and 0x17) 1 - Support Treble command. 0 - Not support Treble command. SW - Subwoofer command flag.