The maximum sinking current of each pin of the G0 or G1 camera is
100 mA. If the mount does not treat the autoguider port as logical input
only, but switches the guiding motors directly by these signals, a relay box
must be inserted between the camera and the mount. The relay box ensures
switching of currents required by the mount.