Toro 25430A Operator's Manual page 47

Traction unit
Hide thumbs Also See for 25430A:
Table of Contents

Advertisement

Battery Charging Table
Charger Setting
4 to 6 amperes
25 to 30 amperes
5. When the battery is fully charged, unplug the charger
from the electrical source, then disconnect the charger
leads from the battery posts (Figure 57).
Replacing a Fuse
1. Remove the right side panel; refer to Removing the
Side Panels (page 35).
2. Rotate the battery-disconnect switch counterclockwise
to the Off position (Figure 58).
Figure 58
1. Battery-disconnect switch
in the On position
3. Replace the open (blown) fuse in the fuse block with a
new fuse that has an equivalent amperage value (Figure
59).
Charging Time
30 minutes
10 to 15 minutes
2. Battery-disconnect switch
in the Off position
1. Fuse block
4. Rotate the battery-disconnect switch clockwise to the
On position (Figure 17).
5. Install the right side panel; refer to Installing the Side
Panels (page 36).
47
Figure 59

Hide quick links: