Cab Maintenance

Cleaning the Cab Air Filters

Service Interval: Every 250 hours (Replace them if they are
torn or excessively dirty.)
1. Remove the screws and grates from over both the
in-cab and rear cab air filters
1
Figure 85
1. Filter
2. Grate
Figure 86
1. Filter
2. Grate
2. Clean the filters by blowing clean, oil free, compressed
air through them.
(Figure
85).
3
3. Screw
1
2
2
3
3. Screw
Important: If either filter has a hole, tear, or other
damage, replace it.
3. Install the filters and grate, securing them with the
thumb screws.
Cleaning the Air Conditioning
Coil
Service Interval: Every 250 hours (Clean more frequently in
2
1. Stop the engine and remove the key.
2. Remove the 6 nuts and washers from the bottom of the
rear of the cab
1
g028378
2
1. Washer
3. Remove the cabin roof of the cab by removing the 22
bolts that secure the roof
g028379
58
extremely dusty or dirty conditions)
(Figure
87).
Figure 87
2. Nut
(Figure
88).
1
2
g028380