Maintenance; Changing The Compressor Oil - General International AC1104 Setup And Operation Manual

10.5 gallon vertical oil-lubricated air compressor
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE

DAILY
(or before each use)
1. Check oil level
2. Drain condensation from the air tank.
3. Check for any unusual noise or vibration.
4. Be sure all nuts and bolts are tight.
WEEKLY
1. Clean breather hole on Oil Breather Cap.
MONTHLY
1. Inspect air system for leaks by applying soapy water to all joints. Tight-
en these joints if leaks are discovered.
6 MONTHS
(or after 250 hours of operation - whichever comes first)
1. Change Air Compressor Oil.
NOTE: Change oil more often if Air Compressor is used near paint
spraying operations or in dusty environments.
CHECKING THE COMPRESSOR OIL
1. Place Air Compressor on level surface. The oil level should be at the
red dot on the Oil Sight Glass.
2. If oil level is low, remove Oil Breather Cap and add enough oil to bring
the oil level to the red dot on the Oil Sight Glass.
3. Replace Oil Breather Cap before starting compressor.

CHANGING THE COMPRESSOR OIL

NOTE: This compressor uses only SAE 5W-30 motor oil.
Oil will begin to drain as Oil Sight Glass is loosened. Place a funnel and
oil pan in place BEFORE loosening Oil Sight Glass.
1. Remove the Oil Sight Glass by turning counter clockwise with wrench.
2. Once Oil Sight Glass is removed, tilt Air Compressor backwards to
allow all of the oil to drain out of the crankcase.
3. Once oil is drained, replace Oil Sight Glass and securely tighten in
place with a wrench. Be careful not to overtighten the Oil Sight Glass,
as this could damage the rubber seal.
4. Place Air Compressor on level surface.
5. Remove the Oil Breather Cap.
6. Slowly pour the oil into the oil fill hole, until the oil level rises to the
center of the red dot on the Oil Sight Glass.
7. Install the Oil Breather Cap into the oil fill hole.
8. Firmly hand tighten the Oil Breather Cap by turning clockwise.
STORAGE
When storing your tool:
1. Be sure the tool is turned OFF.
2. Unplug the tool from power source.
3. Rotate the regulator to set the outlet pressure to zero.
4. Release air pressure from all hoses and air tank(s).
10