The CH0/CH1 receives environment light and generates environment light value by
processing the data internally. Then the system automatically adjusts the LCD brightness
according to the environment light value. The approach sensor is to prevent the phone from
misoperations caused by the contact of the face and touch panel. As a result, if the inferred
emitted by the LED inside the chip is blocked, it will be reflected. Then the sensor will
receive the reflected light through the photodiode and identify the obstacle position. When the
approach status achieves a certain threshold, the system triggers the operation to shut down
the touch panel.
Troubleshooting process
Failure: The approach sensor is faulty.
Solution: