DIP SWITCH SETUP

Before you install the camera, you should set the DIP
switches to confi gure the camera ID, Baud rate, and
communication protocol.
Protocol
Auto Select
ID Setting (1~255)
Camera ID Setup
ID number of camera is set using binary number.
The example is shown bellow.
Pin
1
2
ID Value
1
2
ex) ID=5
on
off
ex) ID=10
off
on
The range of ID is 0~255. Factory default of
Camera ID is 1.
If you want to control a certain camera, you must
match the camera ID with Cam ID setting of DVR
or Controller.
Communication Protocol Setup
ON
ON
1
2
3
4
Buad Rate
RS-485
Terminate
3
4
5
6
7
8
4
8
16
32
64 128
on
off
off
off
off
off
off
on
off
off
off
off
5
6
7
8
Installation
Select the appropriate Protocol with DIP switch
combination.
Switch State
Pin1
Pin2
Pin3 Pin4
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
If you set the protocol as Auto Protocol, camera
will automatically recognize the kind of Protocol.
Auto Protocol supports Pelco-D and Samsung Protocol.
If you want to control using DVR or system
keyboard, their protocol must be identical to
camera. Otherwise, you can not control the camera.
If you changed camera protocol by changing DIP S/W,
the change will be effective after you reboot the camera.
Factory default of protocol is "Auto Protocol
Communication Baud rate Setup
ON
ON
1
2
3
Select the appropriate Baud rate with DIP switch
combination.
Switch State
Pin5
Pin6
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
Factory default of Baud rate is "9600 BPS"
Protocol
OFF
Auto Protocol
OFF
Pelco-D
OFF
Pelco-P
OFF
Samsung
4
5
6
7
8
Protocol
Pin7
OFF
2400 BPS
OFF
4800 BPS
OFF
9600 BPS
OFF
19200 BPS
ON
38400 BPS