Download Print this page

Electrolux Icon E30GC70FSS Installation Instruction page 2

Gas drop-in, deep sump cooktop
Hide thumbs Also See for Icon E30GC70FSS:

Advertisement

Gas Drop-In, Deep Sump Cooktop
E30GC70FSS
2
1
/
" minimum distance between
2
rear edge of cutout and nearest
vertical combustible surface
25"min.
30" Gas Drop-In, Deep Sump Cooktop Specifications
Product Weight – 43 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.001 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
Amps @ 120 Volts = 0.008 Amps
Always consult local and /or national electric and gas codes.
Recommended location for grounded 120V outlet is on rear wall in an
8" wide by 10" high area, positioned 22" above floor surface and
12" to right side of cooktop centerline. Access to underside of cooktop
and junction box must be provided for inspection and service.
Cooktop ships with 3/4" factory regulator.
Lp conversion kit supplied.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
250 Bobby Jones Expressway
USA
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
E30GC70FSS 05/08
13"
max.
cabinet
depth
19"
19
1
/
" min.
8
19
3
/
" max.
4
24"
Augusta, GA 30907
1-877 -4electrolux (1-877 -435-3287)
1-800-265-8352
30"
21
3
/
"
30"
4
27"
8" min.*
Opening to route 48" power
cable & gas supply
Allow 2-1/2" minimum distance between rear edge of cutout to nearest
combustible surface above countertop.
Allow 7" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
Drawers cannot be installed beneath this cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Gas Drop-In, Deep Sump Cooktop model E30GC70FSS is approved to
be used over any Electrolux ICON
Cooktop Installation Over 30" Electric Single Wall Oven Specifications
and drawing on web.)
Gas Drop-In, Deep Sump Cooktop model E30GC70FSS is approved
to be used in combination with an Electrolux ICON
(Refer to Drop-In Cooktop / Downdraft Vent Countertop Preparation
Specifications and drawing on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
Grill / Griddle – (318251603).
Simmer Plate – (318254200).
Wok Ring – (318254301).
Black Burner Knob Kit – (318242222).
electroluxicon.com
electroluxicon.ca
© 2008 Electrolux Home Products, Inc.
30" min. for
unprotected cabinet
18"
24" min. for
min.
protected surface
7" min. to nearest
4
1
/
"
4
combustible wall
(either side of unit)
27
1
/
"min.
4
28
1
/
"max.
2
* Includes a 5"space beneath
cooktop for connection to
gas supply line
Single Wall Oven. (Refer to Gas
Downdraft Vent.
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Printed in the U.S.A.

Advertisement

loading