Timing Chart - LG FLATRON T710P Service Manual

Hide thumbs Also See for FLATRON T710P:
Table of Contents

Advertisement

VIDEO
SYNC
<< Dot Clock (MHz), Horizontal Frequency (kHz), Vertical Frequency (Hz), Horizontal etc... (µs), Vertical etc... (ms) >>
H/V
Sync
Mode
Frequency
Polarity
Sort
H
37.50
1
V
74.99
H
+
53.68
2
V
+
85.07
H
+
68.677
3
V
+
85.00
H
+
79.976
4
V
+
75.025
* No Composite Mode.

TIMING CHART

 
B
C
F
D
Total Period
Video Active
Blanking Time
(A)
Time (B)
26.67
20.32
13.335
12.802
18.63
14.22
11.755
11.178
14.561
10.836
11.764
11.182
12.504
9.481
13.329
12.804
A
E
Sync Duration
(E)
(C)
6.35
2.03
0.533
0.080
4.41
1.14
0.577
0.056
3.725
1.016
0.582
0.044
3.022
1.067
0.525
0.038
- 7 -
Front Porch
Back Porch
Resolution
(F)
(D)
0.51
3.81
0.026
0.427
0.57
2.70
0.018
0.503
0.508
2.201
1024 X 768
0.014
0.524
0.119
1.837
1280 X 1024
0.013
0.475
640 X 480
800 X 600

Hide quick links: