Line Filter(2 X 6.8Mh) - Akai DVP6333KDM Service Manual

Table of Contents

Advertisement

5.5 LINE FILTER (2 X 60mH)
ELECTRICAL DATA
Inductance: L1-2=L3-4-30mH - 15% - +20%
Resistance: R 1-2 = R 3-4 = 1.5 ohm (max)
Rated current: Irms = 0.50 A
(F= 1 Khz V= 1 Vms)
LEAKAGE INDUCTANCE
L 1-2 = L 3-4
100+/- 20%uH
1
2
NOTES
DVD Service Manual
CIRCUIT DIAGRAM
4
3
23

Advertisement

Table of Contents
loading

Table of Contents