GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations. The appliance
has been designed for use in the ducting version (air exhaust
to the outside – Fig.1B), filtering version (air circulation on
the inside – Fig.1A).

SAFETY PRECAUTION

Take care when the cooker hood is operating simultane-
ously with an open fireplace or burner that depend on the air
in the environment and are supplied by other than electrical
energy, as the cooker hood removes the air from the environ-
ment which a burner or fireplace need for combustion. The
negative pressure in the environment must not exceed 4Pa
(4x10-5 bar). Provide adequate ventilation in the environment
for a safe operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
Before connecting the model to the electricity network:
- control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualified
electrician.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
- To connect the device to the power supply through a plug
with a 3A fuse or to the two wires of the two-phase protected
by a 3A fuse.
Warning !
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood
D) Avoid free flame, as it is damaging for the filters and
a fire hazard
E) Constantly check food frying to avoid that the over-
heated oil may become a fire hazard
F) Disconnect the electrical plug prior to any mainte-
nance.
G) This appliance is not intended for use by young children
or infirm persons without supervision
H) Young children should be supervised to ensure they do
not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions
This appliance conforms to the European Directive EC/2002/96,
Waste Electrical and Electronic Equipment (WEEE). By making
sure that this appliance is disposed of in a suitable manner, the
ENGLISH
user is helping to prevent potential damage to the environ-
ment or to public health.
The symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to
a suitable electric and electronic appliance recycling collec-
tion point. Follow local guidelines when disposing of waste.
For more information on the treatment, re-use and recycling
of this product, please contact your local authority, domestic
waste collection service or the shop where the appliance was
purchased.

INSTALLATION INSTRUCTIONS

Assembly and electrical connections must be carried out
by specialised personnel.
• Electric Connection
The appliance has been manufactured as a class II, therefore
no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indi-
cated on the description label. Where a plug is provided, the
cooker hood must be installed in order that the plug is easily
accessible. An omnipolar switch with a minimum opening of
3mm between contacts, in line with the electrical load and
local standards, must be placed between the appliance and
the network in the case of direct connection to the electrical
network.
• The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 45 cm. If a connection tube
composed of two parts is used, the upper part must be placed
outside the lower part. Do not connect the cooker hood ex-
haust to the same conductor used to circulate hot air or for
evacuating fumes from other appliances generated by other
than an electrical source.
- In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which has
the same diameter as the air exhaust outlet hole. If a pipe
with a smaller diameter is used, the efficiency of the product
may be reduced and its operation may become noisier.
Attention!
• Before proceeding with the installation, to be able to move the
hood more easily, complete the following operations:
- Open the front panel of the hood as in Fig. 2 - stage 1.
- Remove the anti-grease filterl by pulling the handle, as shown
in Fig. 2 - stage 2.
Wall mounting
Trace the bottom side of the hood on the wall. Consider the
measurements shown in Fig. 3 and minimum distance from
the cooking surface.
- Mark and drill the holes, following the measurements
shown in Fig. 3.
- Fasten the 4 anchors A Fig. 3.
- Fasten bracket C to the wall using the 2 screws B Fig. 3.
- 24 -