Viking VCCI3608 Installation Instructions Manual

Viking VCCI3608 Installation Instructions Manual

Built-in chimney-style hoods

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
PROFESSIONAL SERIES
BUILT-IN CHIMNEY-STYLE HOODS
N N O O T T E E : : I I F F I I N N S S T T A A L L L L I I N N G G H H O O O O D D W W I I T T H H W W A A R R M M I I N N G G S S H H E E L L F F P P A A N N E E L L , , I I N N S S T T A A L L L L W W A A R R M M I I N N G G S S H H E E L L F F P P A A N N E E L L F F I I R R S S T T . .
I I M M P P O O R R T T A A N N T T - - P P L L E E A A S S E E R R E E A A D D A A N N D D F F O O L L L L O O W W
•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National
Electrical Code, ANSI/NFPA 70-latest edition.
•Check with a qualified and trained installer or local codes for makeup air requirement, if any.
•The installer should leave these instructions with the consumer who should retain for local inspector' s use and for future reference.
This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off
at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn
off the electricity to the hood from the power supply before servicing or cleaning.
Viking hoods are equipped with variable speed controls for blowers. These units will not function with a single speed ventilator.
All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator
kit will void the hood warranty.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, RANGEHOODS MUST BE INSTALLED
WITH THE VENTILATORS THAT ARE SPECIFIED ON THEIR CARTON INDICATING SUITABILITY WITH THIS MODEL.
OTHER VENTILATORS CANNOT BE SUBSTITUTED.
T T O O R R E E D D U U C C E E T T H H E E R R I I S S K K O O F F F F I I R R E E , , E E L L E E C C T T R R I I C C A A L L S S H H O O C C K K , , O O R R I I N N J J U U R R Y Y T T O O P P E E R R S S O O N N S S , , O O B B S S E E R R V V E E T T H H E E F F O O L L L L O O W W I I N N G G : :
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
2. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards
such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
3. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
4. Ducted fans must always be vented to the outdoors.
5. W W A A R R N N I I N N G G !: To reduce the risk of fire, use only metal ductwork.
6. C C A A U U T T I I O O N N !: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air
into spaces within walls or ceilings, or into attics, crawl spaces, or garages.
7. C C A A U U T T I I O O N N ! ! : To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models
manufactured by Viking, model numbers - DEV900/DEV1200, VEV900/VEV1200, or DEV1500, VEV1500 or integral
blowers manufactured by Viking, model numbers - DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or
VIV1200. N N O O T T E E - Please refer inside for specific canopy/blower combinations.
T T O O R R E E D D U U C C E E T T H H E E R R I I S S K K O O F F A A R R A A N N G G E E T T O O P P G G R R E E A A S S E E F F I I R R E E : :
1. Never leave surface units unattended at high setting. Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming foods. (i.e. Crepes suzette, Cherries
jubilee, Peppercorn beef flambe).
3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
WARNING
WARNING
WARNING
1
VIKING
111 FRONT STREET
GREENWOOD, MISSISSIPPI 38930 USA
(662) 455-1200

Advertisement

loading

Summary of Contents for Viking VCCI3608

  • Page 1 Viking hoods are equipped with variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator kit will void the hood warranty.
  • Page 2 B B A A S S I I C C S S P P E E C C I I F F I I C C A A T T I I O O N N S S I I N N T T E E R R I I O O R R A A N N D D E E X X T T E E R R I I O O R R P P O O W W E E R R H H O O O O D D S S W W A A L L L L H H O O O O D D S S R R E E C C O O M M .
  • Page 3: Wall Installation

    HEIGHT OF HOOD The bottom of the hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (175.3 cm) above the floor. The bottom of the hood should never be more than 72”...
  • Page 4: Electrical Supply

    PREPARING FOR HOOD INSTALLATION Plan where the ductwork will be located. See pages 11-14 for rough-in dimensions. Install proper-sized duct work, and roof or wall cap for the type of blower you are using. Recommended hood locations for the most common installations are shown on page 2.
  • Page 5 INSTALLING THE WALL HOOD DUCT COVER 1. Measure from top of the canopy to ceiling and subtract 1/8” (0.3 cm) for clearance. 2. Place the duct cover top inside the duct cover base and lower until desired height is found. (To eliminate scratches, make a mark on the duct cover top for the desired lowering point by subtracting 18”...
  • Page 6 Holes must be drilled. 6. Install blower. (See ventilation kit installation.) Model “A” “B” “C” VCCI3608 12” (30.5 cm) 6” (15.2 cm) 12” (30.5 cm) VCCI3609 12” (30.5 cm) 6”...
  • Page 7 VENTILATOR KIT INSTALLATION VENTILATOR KIT INSTALLATION DIV600 DIV300 (Also see instructions supplied with ventilator kit) (Also see instructions supplied with ventilator kit) 1. Choose the correct VENTILATOR MOUNTING PLATE 1. Attach DAMPER to VENTILATOR, as shown, using for your hood series. three (3) HEX SCREWS (provided).
  • Page 8 VENTILATOR KIT INSTALLATION DIV1200 (ALSO SEE INSTRUCTIONS SUPPLIED WITH VENTILATOR KIT) 1. Remove REAR FILTER RAIL from hood. 2. Lift VENTILATOR into position inside the hood. 3. Engage two (2) TABS on ventilator into two (2) SLOTS in TOP OF HOOD. Secure ventilator to THREADED STUDS with two (2) HEX NUTS (provided).
  • Page 9 CONNECTING DUCTWORK -EXTERNAL POWER DEV900/DEV1200/DEV1500 (Also see instructions supplied with ventilator kit) 1. Run 10” (25.4 cm) round steel ductwork from external blower to the installation location. For best performance, use the straighest possible duct run and the fewest number of elbows. Tape all joints. 2.
  • Page 10 ROOF INSTALLATION EXTERIOR-POWER VENTILATOR DEV900-EXTERIOR POWER VENTILATOR KIT (900 CFM) 1. Locate the blower on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (TV leads, electrical lines, etc.).
  • Page 11 WALL INSTALLATION EXTERIOR-POWER VENTILATOR DEV900-EXTERIOR POWER VENTILATOR KIT (900 CFM) 1. Choose a position on the outside wall. Min. 24” (61.0cm) from ground may vary depending on local codes or location. Make sure no wall studs, pipes or wires run through the opening area 2.
  • Page 12 ROOF INSTALLATION EXTERIOR-POWER VENTILATOR DEV900-EXTERIOR POWER VENTILATOR KIT (900 CFM) 1. Locate the blower on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (TV leads, electrical lines, etc.).
  • Page 13 WALL CUTOUTT WALL INSTALLATION EXTERIOR-POWER VENTILATOR EXTERIOR POWER VENTILATOR KIT 3” 1. Choose a position on the outside wall. Min. 24” (61.0cm) (7.6 cm) from ground may vary depending on local codes or 14 11/16” location. Make sure no wall studs, pipes or wires run (37.3 cm) through the opening area 2.
  • Page 14: Exterior Ventilator Dimensions

    EXTERIOR VENTILATOR DIMENSIONS DEV1200 DEV1500 DEV900 10” (25.4 cm) diameter Opening for wiring 20 3/4” (52.7 cm) 29 1/2” (74.9 cm) 28 1/4” (71.8 cm) 10 1/8” (25.7 cm) 24 1/2” (62.2 cm) 15 1/2” (39.4 cm) 22 1/8” 10” (25.4 cm) (56.2 cm) diameter 14”...
  • Page 15 WALL HOOD DIMENSIONS 30”/36”/42” W. PROFESSIONAL CHIMNEY HOODS 7 7 1 1 / / 2 2 ” ” ( ( 1 1 9 9 . . 1 1 c c m m ) ) 8 8 ” ” ( ( 2 2 0 0 . . 3 3 c c m m ) ) 2 2 9 9 7 7 / / 8 8 ”...
  • Page 16 WALL HOOD DIMENSIONS 48”/54”/60”/66” W. PROFESSIONAL CHIMNEY HOODS 4 4 7 7 7 7 / / 8 8 ” ” 2 2 3 3 1 1 5 5 / / 1 1 6 6 ” ” 1 1 8 8 ” ” 4 4 8 8 ”...
  • Page 17 ISLAND HOOD DIMENSIONS 36”/42” W. PROFESSIONAL CHIMNEY HOODS 900 CFM External 600 CFM Internal Ventilation Installation Ventilation Installation 8 8 ” ” ( ( 2 2 0 0 . . 3 3 c c m m ) ) 900 CFM External 600 CFM Internal Ventilation Installation Ventilation Installation...
  • Page 18 ISLAND HOOD DIMENSIONS 54”/66” W. PROFESSIONAL CHIMNEY HOODS 5 5 3 3 7 7 / / 8 8 ” ” 2 2 6 6 1 1 5 5 / / 1 1 6 6 ” ” 1 1 8 8 ” ” 5 5 4 4 ”...
  • Page 19 WIRING DIAGRAM BUILT-IN HOODS REFER ONLY TO FEATURES EQUIPPED WITH THIS UNIT...
  • Page 20 VIKING 111 Front Street • Greenwood, Mississippi 38930 USA • (662) 455-1200 Specifications subject to change without notice (PS0205VR) F20251D...