10.
Connect the lamp connector properly
and place as drawing before lamp
compartment cover installation back.
Lamp connector must be installed flush
with the connector base as shown in the
image below. A gap between the lamp
connector and the connector base will
cause damage to the projector. The
following images illustrate correct and
incorrect lamp connector installations.
11.
Replace the lamp compartment cover
on the projector and tighten the
captive screw.
12.
Restart the projector.
Do not turn the power on with the lamp cover removed.

Resetting the lamp timer

13.
After the startup logo, open the On-Screen Display (OSD) menu. Go to the
SYSTEM SETUP: Advanced > Lamp Settings menu. Press MODE/ENTER.
The Lamp Settings page displays. Highlight Reset lamp timer. A warning
message displays asking if you want to reset the lamp timer. Highlight Yes and press
MODE/ENTER. The lamp time will be reset to '0'.
Do not reset if the lamp is not new or replaced as this could cause damage.