  • Page 1 ISO 9001 : 2008 Pneumatic Straight Grinder STRAIGHT GRINDER SG-6K SG6K Operation & Maintenance Guide Sheet 1 of 5 FF - MM - 75 REV - 0...
  • Page 2: Troubleshooting

    Pneumatic Straight Grinder, SG-6K Operation and Maintenance Guide AIR SUPPLY : To enable the tool to function satisfactorily, it is essential that a constant 90 psi pressure of clean, dry air is supplied to the hose connection (18). A short leader hose of 16mm I.D should be attached to the tool and the length of the pipe should be less than 12 meters.
  • Page 3 Pneumatic Straight Grinder, SG-6K Operation and Maintenance Guide Clean all parts in suitable solvents. Examine them for wear and tear. Replace any damaged components. Coat parts with light oil and re-assemble carefully in reverse sequence. LUBRICATION REQUIREMENTS : Always install a line lubricator on the air line as close to the tool as possible. A filter-regulator lubricator unit (FRL) is strongly recommended.
  • Page 4 Pneumatic Straight Grinder, SG-6K Exploded View FF - MM - 75 REV - 0 Sheet 4 of 5...
  • Page 5 Pneumatic Straight Grinder, SG-6K Assembly And Part List Item No. Part Number Description 455 21 04 Spindle Nut 455 21 05 Wheel coller 455 40 26 Washer for wheel Grinding wheel 150 40 25 Nut M6 320 01 36 Plain washer M6 298 00 73 Hex.