SM103
DOOR/WINDOW DETECTOR
The Door/Window Detector is a Z-Wave
TM
with any Z-Wave
enabled network. Z-Wave
TM
Z-Wave
logo can also be used with it regardless of the manufacturer, and ours
can also be used in other manufacturer's Z-Wave
of this Door/Window Detector on other manufacturer's Wireless Controller menu
allows remote turn-on of connected modules and their connected lighting when the
Detector is triggered.
Include to or Exclude from a Z-Wave
In the rear casing, there is a tamper switch which is used to carry out inclusion,
exclusion or reset.
When power is first applied, its LED flashes on and off
alternately and repeatedly at 2-second intervals. It implies that it has not been
assigned a node ID and cannot work with Z-Wave enabled devices. The Detector
will stay "awake" for 10 minutes when power is first applied to allow time for
configuration.
Please get familiar with the terms below before starting the
operations.
Function
Inclusion
Add a Z-Wave enabled device (e.g. Detector) to Z-Wave network.
Exclusion
Delete a Z-Wave enabled device (e.g. Detector) from the network.
Association
After inclusion, you have to define the relationship between devices.
Trough association, device can be assigned as master/slave, and specify
which slave is going to be controlled by which master.
Reset
Restore Detector to factory default.
TM
enabled device and is fully compatible
TM
enabled devices displaying the
TM
enabled networks. Inclusion
Tamper Switch
TM
Network
Description
The table below lists an operation summary of basic Z-Wave functions. Please
refer to the instructions for your Z-Wave
the setup function, and to include/exclude/associate devices.
Function
Description
No node ID
The Z-Wave Controller does not allocate
a node ID to the unit.
Inclusion
1.
Have Z-Wave Controller entered
inclusion mode.
2. Pressing tamper switch three times
within 1.5 second will enter inclusion
mode.
Exclusion
1.
Have Z-Wave Controller entered
exclusion mode.
2.
Pressing tamper switch three times
within 1.5 second will enter
exclusion mode.
Reset
1.
Press tamper switch three times
within 1.5 second.
2.
Within 1 second, press and hold the
tamper switch until LED is off.
3.
IDs are excluded and all of preset
value will be reset to factory default.
Association
1. Have Z-Wave Controller entered
association mode.
2. When pressing tamper switch three
times within 1.5 second, the unit will
emit the NIF which implies that the
unit has entered association mode.
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
1
TM
Certificated Primary Controller to access
LED Indication
2-second on, 2-second
off
LED lights up once
whenever tamper switch
is pressed once.
LED keeps on before
reset function has been
completed.
2-second on, 2-second
off

Advertisement

loading

Summary of Contents for Z-Wave SM103

  • Page 1 ID allocated by Z-Wave Controller means exclusion. Exclusion Delete a Z-Wave enabled device (e.g. Detector) from the network. Failed or success in including/excluding the node ID can be viewed from the Z-Wave Association After inclusion, you have to define the relationship between devices.
  • Page 2: Choosing A Mounting Location

    Choosing A Mounting Location Do not over tighten the fixing screws as this may distort or damage the casing. 6. Fit the Magnet to the moving part of the door/window opposite the Detector The Door/Window Detector is suitable for mounting in dry interior locations only. using the adhesive tape or 19mm fixing screws.
  • Page 3 However, the BASIC_SET command will be also sent to the nodes of Grouping 1. For instance, a lamp module will be turned off after receiving the Z-Wave system or someone that has computer software running a Z-Wave controller. BASIC_SET command.
  • Page 4: Troubleshooting

    BATTERY_GET command via Z-Wave Controller. Once the unit receives the command, it will return BATTERY_REPORT command. The unit will send Troubleshooting Battery_Level = 255 (0xFF) command to the Z-Wave Controller to inform that the unit is in low battery status. Symptom...
  • Page 5 cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.