The commands in this section only provide information about the ATTO FibreCenter 3400. Access this
information using these command line interface commands in a Telnet session over the Ethernet port.
Status
Displays the status of the power supplies and the cooling fans.
Limits:
PP = power supply status; OK = operating, NG=inoperable, NI = missing
FF = cooling fan status: OK = operating
K = L
Action: none
Telnet Status
Returns the Telnet status.
Limits: Status may be narrowed to [1] Telnet session information [2] TCP statistics or [3] Telnet auditing information
Action: none
Version
Displays the firmware version of the rack. The FibreCenter 3400 has two processors. Returns reflect status of the ARM firmware and the Xilinx
firmware.
Limits: n = ARM firmware version; x = Xilinx firmware version
Action: none
7.2 Diagnostic commands
Information: get•Status•000
Return syntax: Status•000•PS1:PP•FAN1:FF•PS2:
PP•FAN2:FF•KEY:K
Return example:
Status•000•PS1:OK•FAN1:OK•PS2:OK•FAN2:OK•KEY:L
Information: get•RACK •000•Telnet•Status• [1|2|3]
Information: get•RACK •000•Version
Return: n.nn-xxx