Fujitsu aoyg14lmca Installation Manual
Hide thumbs Also See for aoyg14lmca:

Advertisement

AIR CONDITIONER

INSTALLATION MANUAL

OUTDOOR UNIT
For authorized service personnel only.
INSTALLATIONSANLEITUNG
AUSSENGERÄT
Nur für autorisiertes Fachpersonal.
MANUEL D'INSTALLATION
APPAREIL EXTÉRIEUR
Pour le personnel d'entretien autorisé uniquement.
MANUAL DE INSTALACIÓN
UNIDAD EXTERIOR
Únicamente para personal de servicio autorizado.
MANUALE DI INSTALLAZIONE
UNITÀ ESTERNA
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
ΕΞΩΤΕΡΙΚΗ ΜΟΝΑΔΑ
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
MANUAL DE INSTALAÇÃO
UNIDADE EXTERIOR
Apenas para pessoal de assistência autorizado.
РУКОВОДСТВО ПО УСТАНОВКЕ
ВНЕШНИЙ МОДУЛЬ
Только для авторизованного обслуживающего персонала.
MONTAJ KILAVUZU
DIŞ ÜNİTE
Yalnızca yetkili servis personeli için.
PART No. 9332983012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the aoyg14lmca and is the answer not in the manual?

Questions and answers

Summary of Contents for Fujitsu aoyg14lmca

  • Page 1: Air Conditioner

    AIR CONDITIONER INSTALLATION MANUAL OUTDOOR UNIT For authorized service personnel only. INSTALLATIONSANLEITUNG AUSSENGERÄT Nur für autorisiertes Fachpersonal. MANUEL D’INSTALLATION APPAREIL EXTÉRIEUR Pour le personnel d’entretien autorisé uniquement. MANUAL DE INSTALACIÓN UNIDAD EXTERIOR Únicamente para personal de servicio autorizado. MANUALE DI INSTALLAZIONE UNITÀ...
  • Page 2: Table Of Contents

    AIR CONDITIONER CAUTION OUTDOOR UNIT Read carefully all security information before use or install the air conditioner. Do not attempt to install the air conditioner or a part of the air conditioner by yourself. INSTALLATION MANUAL This unit must be installed by qualifi ed personnel with a capacity certifi cate for handling 9332983012 refrigerant fl...
  • Page 3: Selecting The Mounting Position

    Thicknesses of Annealed Copper Pipes 2.5. Additional charge Maximum height Nominal Outer Maximum Refrigerant suitable for a piping length of 15 m is charged in the outdoor unit at the factory. Thickness (between indoor and out- diameter diameter length When the piping is longer than 15 m, additional charging is necessary. door) Between 15 m and 20 m, when using a connection pipe other than that in the table, charge 1/4 in...
  • Page 4: Installation Diagram

    5.3. Outdoor unit wiring 4. INSTALLATION DIAGRAM (1) Remove the outdoor unit Switch cover A, B. (2) Remove the outdoor unit cable clamp and Nylon clamp. INDOOR UNIT (3) Bend the end of the cable as shown in the fi gure. (4) Connect the end of the connection cable fully into the terminal block.
  • Page 5: Pump Down

    (1) Check if the piping connections are secure. CAUTION (2) Check that the stems of 2-way valve and 3-way valve are closed fully. (3) Connect the gauge manifold charge hose to the charging port of the 3-way valve (side Match the terminal block numbers and connection cable colors with those of the indoor with the projection for pushing in the valve core).