Teaching-In - Max BC-TS-Sw2-WM User Manual

Boiler controller
Table of Contents

Advertisement

Teaching-in

6
t
eachIng
In order to integrate the MAX! Boiler Controller into a MAX!
system it has to be connected to the MAX! Cube via the MAX!
software first. All settings and programming (e.g. week pro-
grams) can be done via the MAX! software afterwards.
You have to teach-in the two channels (MAX! Central heating
and MAX! Hot water) separately.
Start the local MAX! software and click on "New device".
Press and hold down the first channel button (B) of the
MAX! Boiler Controller for at least 3 seconds to activate
teach-in mode. The channel LED will start flashing green.
1.
The first channel will appear in the software.
Press and hold down the second channel button (D) of the
MAX! Boiler Controller to activate teach-in mode of the
second channel.
The second channel will appear in the software as well.
Click on "Next" in the software to give the device a name
and assign it to a room.
The MAX! Boiler Controller is now integrated into the
system and can be configured for each room via the MAX!
software or the smartphone app.
14
-
In
2.
> 3 s