Seeley magiq Installation Manual
Hide thumbs Also See for magiq:

Advertisement

INSTALLATION MANUAL
MagIQ Touch Controller
(English)

Advertisement

Table of Contents
loading

Summary of Contents for Seeley magiq

  • Page 1 INSTALLATION MANUAL MagIQ Touch Controller (English)
  • Page 2: Table Of Contents

    • Cables used for the MagIQ Touch Controller GENERAL MENU are 26AWG, 7/016, 6 core flat. COOLER & HEATER MENUS • 20m/66" cable is supplied with each Seeley cooler or heater • 40m/131" cable is also available SERVICE MENU • Supplied cables should not be altered. CONTROLLER OR SYSTEM RESET ALWAYS route cables at least 300mm / 12"...
  • Page 3: Mounting The Controller

    • Do not locate in strong drafts or in dead spots such as cupboards/drawers. • Always seal the cable entry hole. Hot or cold air coming through the wall may interfere with the temperature measurement. CAUTION! Always make sure there are no electrical cables, gas or water pipes, or the like, behind where you intend to drill. ILL1585-A STEP 3 ILL1586-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 4 ILL1587-A ILL1590-A ILL1589-A Important! The cable hole should be positioned centrally Alternatively, a standard stud mounting bracket within the rectangular window in the mounting bracket. (used for wall plates) can be used with plasterboard walls. ILL1597-A Drill a 16mm hole for cable access, and two smaller holes for the wall plugs provided (5mm holes for plasterboard walls or 6mm holes for brick walls). ILL1591-A ILL1588-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 5 Important! Take care not to damage the cable or plug during this ILL1593-A process. STEP 2 Important! Drafts within the wall cavity can impact the temperature reading of the wall control. We recommend that the cable access hole be sealed, but in such a way that the cable can still retreat into the wall cavity. ILL1594-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 6: Connecting The Controller

    CONNECTING THE CONTROLLER CONNECTING THE CONTROLLER cont SINGLE COMPONENT INSTALLATION (NO ZONES) Select “ALL NEW SYSTEM” option and start the “System Installation Wizard”. Ensuring the Controller is properly connected power up the heater/cooler. ILL1610-A Accept “01” as the number of coolers/heaters to be installed. ILL1595-A To activate the Controller screen, press the button to the right. ILL1611-A ILL1521-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 7: Multiple Component Installations

    AT A TIME as prompted by the Controller. If more than one component of the same device type is connected at the same time there is a risk of communication corruption and the system will not function correctly! The system installation is complete once all components have been detected. ILL1615-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 8: Settings Menu

    Navigate through the menus by tapping the heading tabs at the top of the screen. ILL1616-A Choose between MANUAL or PROGRAM modes or access SETTINGS menu: ILL1618-A ILL1619-A All the menu items are listed on the left hand side of the screen. ILL1617-A For detailed information on the operation screens refer to the MagIQ Touch Controller Owner’s Manual. ILL1620-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 9: General Menu

    • System or Controller Reset COOLER & HEATER MENUS ILL1621-A The COOLER and HEATER menus include settings or information Some menu items are locked with a pin code to related to the specific Seeley International cooling or heating discourage customer access. The pin code is 7378. products installed within the system. More information about the specific settings of these products is provided in the separate product installation guide ILL1622-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 10: Service Menu

    The SERVICE menu contains information and functions Screen’ for each component installed in the system. This screen for competent service personnel. can be used as a troubleshooting tool. ILL1624-A Access is locked with a service pin code. The pin code is 7378. ILL1627-A On this screen the status of the component is displayed and can be modified. ILL1625-A Once the pin code is entered you will have access to component specific information such as model number, serial number, etc. ILL1628-A ILL1626-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 11: Controller Or System Reset

    Navigate through the menu as before until you reach the ‘Service Operating Screen’. ILL1632-A Note! Resetting the whole system will mean that every component connected to the wall control will be given the factory default address. After resetting a whole system it will be necessary to go through the ‘System Installation Wizard’ again from the start. ILL1631-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 12: Managing Components

    REPLACE the faulty component or install it as a ILL1633-A new component. Choose REPLACE. ILL1635-A Important! If you are replacing more than one faulty component, it is important that new components of the same type are connected ONE AT A TIME. MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 13: Removing Components

    REMOVING COMPONENTS cont If a component is to be removed from the installation and never At this point, disconnect the component to be removed and replaced, it can be deleted from the Controller’s memory. press the MODIFY button. This should cause the Controller to display a warning message where the component can deleted. Go to the GENERAL menu in SETTINGS. Scroll down to the menu item ‘SYSTEM CONFIGURATION’. ILL1638-A ILL1636-A After entering the correct pin-code (7378), the screen will display a list of all components in the installation (both functional and faulty). ILL1637-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 14: Managing The Controller

    Important! Any pre-used controller must be reset before it is connected to another existing system. ILL1639-A Once the controller has been reset, the installation process The controller will scan for one type of component at a time. is the same as if it were new. The operator can skip to the next scan once they see all components of a particular type have been found. ILL1596-A ILL1640-A MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 15: Fault Routine

    So long as a fault remains in the system, a small fault icon will be displayed at the right hand side of the lower taskbar. By pressing this icon, the operator can access information about all current faults. ILL1643-A ILL1642-A ILL1644-A For more information on product specific fault codes, please refer to the installation manual provided with the product or contact a local service agent. MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 16: Power Outages

    “STATUS INFORMATION DISPLAY” option on in the SETTINGS menu. The controller is in Review the schedule PROGRAM mode and via the EDIT button on the current time period the PROGRAM home specifies the cooler/ screen. heater be “OFF”. MAGIQ TOUCH CONTROLLER INSTALLATION MANUAL |...
  • Page 17: Seeley International

    Warranty Service Australia 1-300-650-644 seeleyinternational.com It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. seeleyinternational.com 862699-A AU 1307...