3. TD-101 includes

the dialer, 2.5m telephone cable, set of screws, manual, and
F
emergency
button marking label. Model TD-101W, in
addition, includes a wireless remote control (RC-10)
4. Installation
We recommend professional installation of the dialer. The
dialer should be fixed in the desired location using the two
included screws (see drilling diagram at the end of this manual).
First, partially screw in the top screw and slide the screw head
through the hole in the upper part of the TD-101 rear panel. Then
open the dialer terminal compartment cover and mark the position
of the second screw. Place cables through the hole for cables in
the rear panel before installing the second screw. Do not open the
upper part of TD-101 housing during installation; doing so will
result in voiding of warranty.
4.1. Terminal Description
IN
telephone line input (inlet of the telephone line to
the house)
OUT
telephone line output (phone, fax etc.); in the stand by mode the line operates as normal. If
triggered, the TD-101 will use the line (switch off the other devices)
+12V, GND
external power supply (12VDC, max. 100mA)
TAMPER
tamper switch (normally closed contacts)
IN1 +/-
positive and negative poles of the first trigger input
IN2 +/-
positive and negative poles of the second trigger input
5. Operation
When power is supplied, the dialer will perform an automatic self test (red LED turns on for
10 seconds). Then the TD-101 will enter the stand by mode. In this mode, the TD-101 is waiting for an
input form either the keypad or the trigger inputs. For correct function of the dialer, the telephone
numbers and messages must first be programmed (see chapter 6.).
5.1. What does the dialer do if activated:
seizes the telephone line (switches off all other devices)
checks dial tone, if the tone is not detected, it will try to release the line again
dial the first tel. number and if detects:
ringing tone, it will send the message and will not call this number again
busy signal, it will call next number and then will try to call the previous number again
The red LED will light when the dialer has been triggered. Once the dialer has been triggered, it's dialing
procedure can be terminated by pressing and holding the
possible only when the IN1 and IN2 inputs are not triggered.
Telephone dialer TD-101 / TD-101W
Both TD-101 trigger inputs have built in opto-
couplers. The dialer is triggered when an opto-
coupler current is switched on (factory default),
opposite logic of inputs is programmable (trigge-
ring by the current switching off). There are
many possibilities on how to connect the trigger
inputs - see examples on page 20. Consider
that the dialer reacts only to signals with a
duration of 0.1sec. or longer. Each optocoupler
is ON only if its input terminal voltage is 5 to
20V.
E
key (if enabled in installer level). This is
- 4 -
11.3. Example of TD-101(W) use with different alarm systems
Suggestion of programming for the configuration above
tel. number memories
user mode
setting
record only voice mess. no. 2
data for Monitoring Station
four report codes
can be programmed
installer
mode
(see chapter 8)
setting
logic of IN1 and IN2 inputs
MDJ512 10
Telephone dialer TD-101 / TD-101W
Mem
1, 2 - not used
3, 4 - numbers for alarm voice message
5
- not used
6
- alarm PAGER number and data
disarming
arming
alarm
end of alarm
Normally Closed contacts
- 21 -