Air Heater Assembly - Operation

START-UP

1. Apply main power to unit.
2. Turn on and set air at a minimum of 1 SCFM
with a pneumatic pilot signal to the pressure switch
of at least 1 psig.
3. Adjust temperature to desired setting using
the key pad on face panel (maximum setting is
150°F).
>
Heating the drive-air to between
120°F and 140°F will usually keep the
rotator housing warm enough to prevent
condensation. Use ONLY enough heat to
prevent moisture buildup!
4. The unit is now ready for normal operation.
C A U T I O N
!
>
When turning the air heater off, first
remove power and allow the unit to cool
prior to turning off air flow. Failure to do
so may create excessive heat in the heat-
ing element and may cause permanent
damage or reduced service life of heating
element.