Air Heater Assembly - Installation
USER Key
Press this key in monitoring mode display or setup
mode display returns you to the PV/SV display.
Pressing this key on the PV/SV display allows
you to set the function for uTey under the system
menu (5Y5 Ch 7). (The factory set function for
this key is switching between auto and manual.)
SEL Key
Switches the PV/SV display to the monitoring
mode display or setup mode display. Switches
to setup mode when parameter display and this
key functions as the select key when changing
parameters. Holding this key down in channel
display or parameter display returns you to the
PV/SV display. Pressing this key at PV/SV display
in manual mode, manual output value is shown
in the lower display.
Display
C1/C2 Lamp
Displays the condition of the control output. Lights
ON at 100% output and goes out at 0% output.
For values between 0% and 100%, the output is
indicated by the length of time the lamp flickers.
When acting as a valve control, the C1 lamp will
light with OPEN output, and the CS lamp will flicker
with CLOSE output.
DO1/2/3 Lamp
Lights ON when there is digital output is on state
(DO1, DO2, DO3). The lamp flickers when delay
behavior is on.
PV Display
Displays the measurement value (PV). Displays
the name of the parameter when setting parameters.
>
Expect alarm light to flash when auto
tuning.
LN-9245-00.8
OPERATION PARTS
NOTE
Key
Pressing once will increase the setting value by
one. Holding down the button will continue to
increase the value. It changes SV on the PV/
SV display. It is also used to move between
items in channel screen display and parameter
screen display.
Key
Pressing once will decrease the setting value
by one. Holding down the button will continue
to decrease the value. It changes SV on the
PV/SV display. It is also used to move between
items in channel screen display and parameter
screen display.
DISPLAY
SV Display
Displays the set value (SV). Also can display the
output value during manual mode. Displays the
parameter setting value when setting parameters.
Displays (rEN) during remote SV operation and
5oF
and set value alternately during soft start.
R
SV Lamp
Lights when displaying the set value (SV). Goes
out when displaying the manual output value. The
lamp flickers while performing ramp soak or lamp
SV operations.
MAN/AT/SELF Lamp
Normally lights up during manual mode and blinks
during auto-tuning or self-tuning.
12