C A U T I O N
!
>
Air filters must be located before the
air heater. Heated air may damage air
filters.
>
The use of an in-line lubricator before
the air heater is NOT recommended. Oil
laden air passing across the heating ele-
ments results in burnt contaminates which
will accumulate and plug applicator ports.
This action may cause premature atom-
izer turbine failure.
>
It is the user's responsibility to
ensure clean air at all times. Failures
resulting from contaminated air will
not be covered under warranty.

FRONT PANEL DISPLAY AND FUNCTIONS

FUJI MICRO CONTROLLER "X", MODEL PXG4