Advertisement

5. Lower the left-hand end of the unit into the printer and locate
under the retaining lip on top of the fuser unit.
6. Lower the right-hand end of the oil roller unit down onto
the fuser.
7. Pull the small coloured locking lever to the right of the oil
roller unit towards you (towards the front of the printer) to
lock the oil roller into position.
The coloured labels on the oil roller and the fuser should
now be aligned one above the other.
8. Close the top cover and press down firmly at both sides to
ensure that it locks down.
User's Guide

Resetting Fuser Oil Roller Count

After installing a new fuser oil roller, the page counter for the
roller unit should be reset. This is performed using the User
Menus.
1. Hold down the MENU 1 / Menu 2 key for about 2 seconds
until the menu item COLOR REG ADJUST appears in the
display.
2. Press and release the MENU 1 / Menu 2 key to cycle
through the available items. When the display shows OIL
ROLLER COUNTER press the ENTER key to reset the
roller count.
3. Press the ON LINE key to exit from the User Menu and
return to the ON LINE (ready) condition.