Page 1
INSTALLATION MANUAL AS10V Series AS13V Series AS18V Series AS24V Series...
Page 5
Model //10// 15 //13// 15 //18// 15 //24// 20 The appearance of the unit may be different from the diagram depending on the model.
Page 6
The following accessories are supplied with the air conditioner: The number of each accessory is indicated in parentheses. Accessories in the Indoor Unit Case Installation Plate (1) Installation Plate (1) (**10/13**) (**18/24**) User's Manual and Batteries for Remote Control (1) Installation Manual (1) Remote Control (2) Accessories in the Outdoor Unit Case...
NSTALLING THE IR CONDTIONER Installing and Connecting the Drain Hose of the Indoor Unit When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65-mm hole drilled in the wall, check the following: The hose must The end of the drain Do NOT bend the hose...
NSTALLING THE IR CONDTIONER Connecting the Assembly Cable The outdoor unit is powered from the indoor unit through the assembly cable. If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15 meters. Extend the assembly cable if necessary.
OMPLETING THE NSTALLATION Purging the Connected Pipes The outdoor unit is loaded with sufficient R22 refrigerant for a 5-meter pipe You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause Outdoor unit Indoor unit reduction of cooling capacity and malfunction.
OMPLETING THE NSTALLATION Performing the Gas Leak Tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate) To check for gas leaks on the...
Need help?
Do you have a question about the AS10V Series and is the answer not in the manual?
Questions and answers