Olsen G95V UltraComfort 95V User's Information Manual

Natural and propane gas two stage high efficiency (condensing) warm air furnace

Advertisement

Quick Links

NATURAL AND PROPANE GAS TWO STAGE
HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE
MODELS STARTING WITH G95V
!
WARNING
IF THE INFORMATION IN THESE INSTRUC-
TIONS IS NOT FOLLOWED EXACTLY, A FIRE
OR EXPLOSION MAY RESULT, CAUSING
PROPERTY DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE.
!
WARNING
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTH-
ER FLAMMABLE VAPORS AND LIQUIDS, OR
OTHER COMBUSTIBLE MATERIALS IN THE VI-
CINITY OF THIS OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRICAL
SWITCH; DO NOT USE ANY PHONE IN
YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUP-
PLIER FROM A NEIGHBOR'S PHONE,
OR A CELLULAR PHONE FROM A LO-
CATION WELL AWAY FROM THE BUILD-
ING. FOLLOW THE GAS SUPPLIER'S
INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUP-
PLIER, CALL THE FIRE DEPARTMENT.
DO NOT RE-ENTER THE BUILDING UN-
TIL AUTHORIZED TO DO SO BY THE GAS
SUPPLIER OR THE FIRE DEPARTMENT.
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE INJURY, PROPERTY DAMAGE
OR LOSS OF LIFE. REFER TO THIS MANUAL.
INSTALLATION AND SERVICE MUST BE
PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.
ECR INTERNATIONAL LTD.
P.O. Box 900, 6800 Base Line
Wallaceburg, ON N8A 5E5
Canada
www.ecrltd.com
!
!
An ISO 9001-2000 Certifi ed Company
DO NOT DESTROY THIS MANUAL
Please read carefully and keep in a
safe place for future reference by a
service technician.
IMPORTANT: Read these instruc-
tions thoroughly before attempting to
operate this furnace.
WARNING
!
SHOULD OVERHEATING OCCUR
OR THE GAS BURNERS FAIL TO
SHUT OFF, CLOSE THE MANUAL
GAS VALVE FOR THE FURNACE
BEFORE
SHUTTING
ELECTRICAL POWER TO THE
FURNACE. FAILURE TO DO SO
CAN CAUSE AN EXPLOSION OR
FIRE RESULTING IN PROPERTY
DAMAGE, PERSONAL INJURY OR
LOSS OF LIFE.
BEFORE RESTARTING THE FUR-
NACE,
CHECK
ALL
VENTS AND WIRES FOR DAM-
AGE.
P/N 240006752, Rev. A [04/07]
!
OFF
THE
PLASTIC

Advertisement

loading

Summary of Contents for Olsen G95V UltraComfort 95V

  • Page 1 NATURAL AND PROPANE GAS TWO STAGE HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE MODELS STARTING WITH G95V WARNING DO NOT DESTROY THIS MANUAL Please read carefully and keep in a IF THE INFORMATION IN THESE INSTRUC- safe place for future reference by a TIONS IS NOT FOLLOWED EXACTLY, A FIRE service technician.
  • Page 2: Table Of Contents

    USER’S INFORMATION MANUAL Printed in Canada • Made In Canada TABLE OF CONTENTS CAUTION 1 - Safety Symbols and Warnings .....2 Indicates a potential hazardous situation 2 - Safety Issues ..........2 which, if not avoided, MAY result in minor or 3 - Furnace Operation ........4 moderate injury.
  • Page 3 It is important for these vents to remain clear. Do WARNING not allow moisture, which could freeze, to build up in the vent. If you see moisture building up in the IMPROPER INSTALLATION, ADJUSTMENT, regulator vent, contact your gas supplier. ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PER- WARNING...
  • Page 4: Furnace Operation

    materials to come into contact with the furnace. affected parts have been replaced. 9. Do not allow snow, ice or debris to accumulate 5. Any additions, alterations or conversions re- around the outdoor furnace exhaust and combus- quired in order for the furnace to properly match the tion air intake terminals.
  • Page 5: Routine Maintenance By Homeowner

    9. Turn the manual gas control switch to the to “Furnace Shut-Down Procedure” and call your “ON” position. Installer, service agency or gas supplier. 10. Replace the burner access door, ensuring FURNACE SHUT-DOWN PROCEDURE: that it is properly in place. 1.
  • Page 6 Things to check: with dust. To clean the recovery coil: • Check the furnace for obvious signs of dete- 1. Disconnect electrical power to the furnace. rioration. • Check the venting and combustion air piping 2. Remove the blower access door to ensure that it is still fastened to the furnace.
  • Page 7 10. Replace the blower access door. utes to home comfort. Each pound of condensation formed releases approximately 970 BTUs. Your fur- nace may condense up to ½ gallon (5 pounds) of 11. Restore electrical power to the furnace. water per hour if running continuously. Routine cleaning the interior of the recovery coil This condensation must be properly disposed into should not be necessary.
  • Page 8: Homeowner's Reference Table

    4. When there is a demand for 2 stage heat 5 - HOMEOWNER’S REFERENCE from Thermostat W2 or automatic staging , the control changes the inducer from low to high HOMEOWNER’S REFERENCE TABLE speed. When high pressure switch closes, Model No. the control changes indoor blower speed from Low heat to High heat and energizes high gas output.